2  Technical data

Model

7

10

14

22

29

45

Volume [liter]

7

10

14

22

29

45

Usable bath length A [mm]

240

350

350

350

590

590

Usable bath width B [mm]

210

210

290

290

350

350

Usable bath depth C [mm]

140

140

140

220

140

220

Housing length D [mm]

468

578

578

578

818

818

Housing width E [mm]

356

356

436

436

516

516

Housing height (with flat cover) F [mm]

238

238

238

296

238

296

Housing height (with gable cover) G [mm]

337

337

347

405

343

401

Weight [kg]

11

14

16

17

24

26

Current consume [A]

5,2

5,2

7,8

8,7

10,4

12,2

Power [W]

1200

1200

1800

2000

2400

2800

 Ambient conditions

Ambient temperature 5°C - 40°C
rh max. 80% (no condensation)
Overvoltage Category: II
Contamination degree: 2

Setting temperature range

10ºC to 95ºC on waterbaths 
with activation of the  boiling mode to 100°C, see section 
4.3.1
20ºC to 200ºC on oilbaths

Setting accuracy:

0,1°C

Indication accuracy

0,1°C

 Working temperature range

From 5ºC above ambient temperature on water- 
and oilbaths or 15°C above ambient temperature 
on waterbaths with circulating pump to  nominal 
temperature = maximum temperature (see rating plate)

Summary of Contents for ONE 10

Page 1: ...Waterbath WNE 7 45 WPE 45 Oilbath ONE 7 45 Operating Instructions...

Page 2: ...EXCELLENT page 2...

Page 3: ...monitor 15 4 3 7 Level monitor 15 4 3 8 Setup menu 15 4 3 8 1 Calibration 16 4 3 8 2 Selection of temperature monitor waterbaths only 17 5 Programming example of a programme sequence 17 6 Monitoring...

Page 4: ...erating Instructions is necessary for faultless operation and for any possible claims under warranty If these Instructions are disregarded all claims under warranty guarantee and indemnification are e...

Page 5: ...Weight kg 11 14 16 17 24 26 Current consume A 5 2 5 2 7 8 8 7 10 4 12 2 Power W 1200 1200 1800 2000 2400 2800 Ambient conditions Ambient temperature 5 C 40 C rh max 80 no condensation Overvoltage Cat...

Page 6: ...C electromagnetic compatibility This product is intended to operate on a supply network with a system impedance Zmax at the transfer point building connection of 0 292 Ohm max The user has to ensure t...

Page 7: ...1 4571 Class A in 4 wire circuit for control and monitoring Built in sounder as alarm on overlimit as audible signal at programme end and to acknowledge input key click Warning at low liquid level Co...

Page 8: ...lve The thermostating fluid must be cooled to room temperature before draining Drain the fluid either directly into an appropriate container or connect an appropriate hose to the drain valve Operation...

Page 9: ...rectly into an appropriate container or connect an appropriate hose to the drain valve For safety reasons the flash point of the oil must be at 300 C or higher The manufacturer of the oil may also hav...

Page 10: ...e distribution 4 1 Controls and indications relatively largest heat loss since furthest away from the heated ribs minimum heat loss since very close to the heated ribs bath Insulation heating elements...

Page 11: ...ol while holding down the SET key protection against unintentional alteration If the push turn control is rotated quickly the setpoint is altered in large steps with slow operation it is altered in si...

Page 12: ...e maximum value until the display shows CCC The setting boiling mode is not stored permanently After the bath is switched off and on again the controller shows again the previously selected setpoint C...

Page 13: ...flashes the hold time setting If no hold time has been programmed the hold time is activated immediately and the display alternates between the actual temperature and the running time of the hold tim...

Page 14: ...ter circulation avoids larger temperature differences At a water temperature of e g 90 C the temperature difference in the entire bath is less than 0 36 C Note If the boiling mode CCC has been activat...

Page 15: ...level has fallen so far that the upper of the two Pt100 temperature sensors is above the bath liquid the different temperatures inside and outside the bath liquid cause the symbol to flash the sounder...

Page 16: ...e corrected 1 Set calibration temperature to 70 0 C and set calibration difference to 0 0 C 2 Using a calibrated reference instrument the measured temperature is 69 0 C at a setpoint temperature of 70...

Page 17: ...nt to f ex 90 0 C C 2 Delayed switch on setting Rotate the push turn control until the delay and the symbol flashes With the SET key depressed use the push turn control to set the time f ex 6 00 C 3 H...

Page 18: ...ctual temperature and SP until the setpoint temperature is reached Heating is indicated by the symbol C C Bath holds setpoint temperature SP is de activated or after the setpoint temperature has been...

Page 19: ...after the TB cut out has been activated 1 Switch off the bath and allow it to cool down 2 Rectify the fault e g top up the liquid replace temperature probe and where appropriate contact customer serv...

Page 20: ...the SET key The symbol flashes as warning 7 3 Monitor relay In addition the bath is equipped with an electronic monitor relay If a fault occurs during operation or if the selected setpoint temperatur...

Page 21: ...erature of the thermofluid 9 Level control special equipment 2 different filling levels can be maintained constant if the unit is fitted with a level control system When using water as thermostating l...

Page 22: ...at continuous influence can impair the outfit and function of the water oilbath Please use only detergents and antiliming agents appropriate for stainless steel for the cleaning of the tank and the h...

Page 23: ...integrated digital timer for the hold time starts no earlier than the temperature in the bath has reached the setpoint to least 0 5 C at 95 C nominal temperature resp 2 C at 200 C nominal temperature...

Page 24: ...2004 05 EN 61326 1997 EN 61326 A1 1998 EN 61326 A2 2001 EN 61326 A2 2003 The designated product is in conformity with the European Low Voltage Directive 2006 95 EEC including amendments Council Direc...

Page 25: ...t of domestic refuse For disposal please contact your dealer or the manufacturer Products which are infected infectious or contaminated with health endangering substances are excluded from return Plea...

Page 26: ...8 L level control system 8 21 level monitor 15 liquid level oilbaths 9 liquid level waterbaths 8 low level protection 19 M maintenance 22 Mat Ref 1 4301 6 material quality 6 monitor relay 20 monitor...

Page 27: ...EXCELLENT page 27...

Page 28: ...Memmert GmbH Co KG Postfach 1720 D 91107 Schwabach Tel 49 0 9122 925 0 Fax 49 0 9122 145 85 E Mail sales memmert com www memmert com 24 04 2009 Water Oilbath EXCELLENT englisch D10333...

Reviews: