9.1
Surface-mount installation/flush-mount installation
This manual describes the surface-mount and flush-mount installation of the ventilation
unit.
— For
surface-mount installation
, follow the steps in sections “10 Surface-mount
installation” from page 24 and “11 Installing the ventilation unit” from page 34.
— For
flush-mount installation (optionally with ductwork connection)
, follow the
steps in section “11 Installing the ventilation unit” from page 34.
The ventilation unit is installed once the work described in the installation manuals for
the flush-mount installation kit is complete (see section “1.11 Supplementary docu
— For
U
2
integrated into wall installation
follow the steps in section “11 Installing the
ventilation unit” from page 34.
The ventilation unit is installed once the work described in the installation manual for
the U
2
flush-mount installation kit is complete (see section “1.11 Supplementary docu
9.2
Electrically disconnecting mains cables
During installation, the ventilation unit is connected to the power supply with a mains
cable.
DANGER
Potentially fatal voltages
—
The electrical installation work must only be carried out by a qualified electrician.
— The VDE regulations or any special safety regulations applicable in your country
apply to the electrical installation work.
►
Before starting installation or maintenance work, disconnect the mains cable for
connecting to the ventilation unit on all poles from the mains supply.
► Observe the five safety rules (DIN VDE 0105-100, EN 50110-1) for working on elec
-
trical systems:
— Disconnect from mains (all-pole disconnection of a system from live parts)
— Secure against reconnection
— Check that the system is voltage-free
— Earth and short-circuit
— Cover or block off access to adjacent live parts