Maintenance instructions
M-WRG-II P... / M-WRG-II E ventilation units
Meltem Wärmerückgewinnung GmbH & Co. KG
Am Hartholz 4 · D-82239 Alling
[email protected] · www.meltem.com
VENTILATION THE RIGHT WAY
V E N T I L A T I O N & H E A T R E C O V E R Y
8.11
Insert new outdoor air filter
►
Carefully guide the new outdoor air
filter (item 1 in Fig. 17) into the venti
-
lation unit.
► Make sure that the air filter slides into
the 3 retaining tabs (item 2 in Fig. 17)
on the back wall of the ventilation
unit.
► Place the filter cover (item 3 in
Fig. 17) on the outdoor air filter. Make
sure that the filter cover lies flat on
the intermediate plate (item 4 in
► Turn the filter cover clockwise until
the arrow on the filter cover (item 5 in
Fig. 17) lines up with the arrow for the
locking position (item 6 in Fig. 17). Make sure that the 3 tabs (item 7 in Fig. 17) on the
filter cover engage in the retainers (item 8 in Fig. 17) on the intermediate plate.
► Check the position of the filter cover. The hand grip must be vertical and the arrow
on the filter cover must line up with the arrow for the locking position (see Fig. 7 on
NOTICE
—
The ventilation unit will not work as well if the filter cover is not inserted correctly.
—
Only M-WRG-II FA, part no. 750010, and M-WRG-II FK (activated charcoal filter),
part no. 750020, may be used as the outdoor air filter. The part no. and air filter
class are imprinted on the turquoise end plate of the air filter (item 9 in Fig. 17).
Fig. 17:
Insert new outdoor air filter
1
2
3
4
5
6
7
8
9