7.11
Inserting flexible pipes into the flexible pipe connection
►
Insert the flexible pipes into the openings
in the flexible pipe connection on the wall
box and seal the join with a layer of seal-
ing tape 30 mm wide (item 1 in Fig. 18) or
insert sealing rings. These are available as
accessories M-WRG-FR-DR75 or M-WRG-
FR-DR63 for the corresponding nominal
diameter.
►
Insert the flexible pipe connection into the
fixing plate.
NOTE
►
Run the flexible pipes without forcing or
stresses.
►
Fix the flexible pipes in place with expand-
ing foam. This will improve both the seal
and the insulation.
7.12
Riveting the flexible pipe connection
to the fixing plate
►
Remove the protective cover for the flexible
pipe connection (item 1 in Fig. 19).
►
Use the riveter to fix the flexible pipe con-
nection (item 2 in Fig. 19) to the fixing plate
(item 4 in Fig. 19) with two blind rivets (item
3 in Fig. 19).
►
Push the protective cover (item 1 in Fig. 19)
back into the flexible pipe connection (item
2 in Fig. 19).
7.13
Plastering the wall box and flexible
pipes on the inside
►
Make sure that the signal cover (item 1 in
Fig. 20) is seated in the protective cover
(item 2 in Fig. 20).
►
Make sure that the protective covers (item
3 in Fig. 20) are seated in the flexible pipe
connections.
►
Cut off any excess expanding foam on the
wall box and flexible pipes.
Fig. 18: Fixing a flexible pipe connection with
sealing tape
Fig. 19: Riveting the flexible pipe connection to
the fixing plate