11.7
Connecting the mains cable and control cable (if used)
DANGER
Potentially fatal voltages.
—
The electrical installation work must only
be carried out by a qualified electrician.
—
The VDE regulations or any special
safety regulations applicable in your
country apply to the electrical installation
work.
►
Disconnect the mains cable for
connecting to the ventilation unit on all
poles from the mains supply.
►
Make sure that the mains supply cannot
be switched on again.
NOTE
The ventilation unit may be damaged if the mains or control cable is connected incorrectly.
This will also invalidate the warranty.
►
Connect the neutral conductor N (item N in Fig. 29) and the outer conductor L (item L in
Fig. 29) to the screw terminal of the ventilation unit.
►
Connect the wire for the external control input (if used) (item S in Fig. 29) to the screw
terminal (only for ventilation units with external control input, see Table 5 in section 10.8 on
NOTE
No protective earth (PE) conductor is required.
►
Connect the control cable (if used) to the ventilation unit.
NOTE
Connection of the control cable is described in separate installation instructions (only for certain
ventilation units, see Table 4 in section 10.8 on page 22).
Fig. 29: Connecting the ventilation unit to the mains
power supply
L
N
S