Grid Director 4036E Installation Manual
27
5.7
Label(s)
The following Grid Director 4036E label (example) shows all safety and EMC text and logos
pertaining to the 4036E.
Figure 8: Grid Director 4036E Label (Example)
5.8
Shock and Vibration
Prepare the Grid Director 4036E to ship by carefully following the rail kit installation
instructions, as detailed in
Hardware Installation
(on page
30
). The Grid Director 4036E is
susceptible to shock and vibration if the rail kit installation instructions are not followed
precisely.
The following tables detail the Grid Director 4036E vibration and free fall tests for
transportation.
Table 10: Vibration
Test
Description
Vibration Axes
3 axes (X,Y,Z)
Non-Operating Random
Vibration
Frequency range:
5-300Hz
Vibration level:
Z axis, 1.03g RMS
X,Y axis 0.698g RMS
Vibration test for each axis
60 minutes
Operating Sine
Vibration
Frequency range:
5-500Hz
Vibration level:
0.1G peak
Vibration test for each axis
40 minutes
Operating Shock
Vibration Level
Z axis, 5g peak