![Meler Macro Series Instruction Manual Download Page 67](http://html1.mh-extra.com/html/meler/macro-series/macro-series_instruction-manual_1767094067.webp)
TECHNICAL CHARACTERISTICS
6-1
MA-5052-ENG
MACRO SERIES MELTER MANUAL
6. TECHNICAL CHARACTERISTICS
General
Tank capacity
Pumping rate
(*)
single pump
double pump (per output)
Melting rate
(*)
Number of pumps
Number of hydraulic outputs
Number of electric outputs
Temperatures range
Temperature control
Max. working pressure (at 6 bar)
Max. power supply
one single pump
two single pumps
one double pump
two double pumps
four single pumps
External functions
Electrical requeriments
Workplace temperature
Dimensions (LxWxH)
Weight
(*) Under standard conditions.
50 liters
1, 2.5, 4, 8, 15, 20 y 30 cc/rev
2x0.93, 2x1.86, 2x3.71 y 2x4.8 cc/rev
50 kg/h
Up to 4 single pumps
Up to 2 double pumps
2 per pump
2 or 4 outputs (Standard version)
40 to 200°C (100 to 392°F)
RTD ±0.5°C (±1°F)
Pt-100 or Ni-120
80 bar (1.160 psi)
4.260 W / per phase (2 outputs)
5.560 W / per phase (4 outputs)
4.890 W / per phase (2 outputs)
6.190 W / per phase (4 outputs)
6.720 W / per phase (4 outputs)
Temperatures ok output
Low level signal (optional)
Standby input
External outlet inhibitor
Motor start up input
Motor speed control input
Failures in pumping card output
3N ~ 400V 50/60 Hz + PE
0 to 40°C
1150x510x1825 mm
350 kg
120 liters
1, 2.5, 4, 8, 15, 20 y 30 cc/rev
2x0.93, 2x1.86, 2x3.71 y 2x4.8 cc/rev
120 kg/h
Up to 4 single pumps
Up to 2 double pumps
2 per pump
2 or 4 outputs (standard version)
40 to 200°C (100 to 392°F)
RTD ±0.5°C (±1°F)
Pt-100 or Ni-120
80 bar (1.160 psi)
6.060 W / per phase (2 outputs)
8.260 W / per phase (4 outputs)
6.690 W / per phase (2 outputs)
8.890 W / per phase (4 outputs)
9.010 W / per phase (4 outputs)
Temperatures ok output
Low level signal (optional)
Standby input
External outlet inhibitor
Motor start up input
Motor speed control input
Failures in pumping card output
3N ~ 400V 50/60 Hz + PE
0 to 40°C
1150x875x1825 mm
535 kg
Summary of Contents for Macro Series
Page 1: ...MA 5052 ENG 221220 GLUING SOLUTIONS ADHESIVE MELTER MACRO SERIES INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 32: ...FOCKE MELER GLUING SOLUTIONS 3 12 INSTALLATION This page is intentionally left blank ...
Page 58: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Page 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Page 71: ...ELECTRICAL DRAWINGS 7 1 MA 5052 ENG MACRO SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...