FOCKE MELER GLUING SOLUTIONS
3-4
INSTALLATION
Electrical power connection
Macro series melters are designed to be connected to the electrical power
supply in 3-phase 400 VAC with neutral.
A good ground connection is required in any case.
Consumption figures, according to melter and output configuration, are
included in the table.
Warning:
Risk of electrical shock. Carelessness may cause injury or death.
Install the electrical wall bushing Pg 21 in the area reserved for them,
fastening them to the plate with the appropriate nut.
Open the electric cabinet door as far as possible. Thread the power cord (Ø14-
18 mm) through the electrical wall bushing Pg 21 and fasten it to the inside
anchor, making sure that the cord reaches the power terminals block inside
the cabinet.
Connect each wire in the power cord to its corresponding place on the power
terminals block, as shown in the figures.
Pneumatic connection
If a pneumatically controlled by-pass pressure control valve is installed, the
equipment must have a compressed air supply.
Before connecting the pneumatic power to the melter, make sure the pressure
regulator is completely closed.To do this, turn the regulator handle located on
next to the pressure gauge counterclockwise as far as it will go.
Unit
No. outputs
3 Phases
3 Phases
400 VAC Y
400 VAC Y
1 Single pump
1 Double pump
Macro50
2
18.5 A
21.3 A
4
23.7 A
26.5 A
Macro120
2
26.3 A
25.2 A
4
31.6 A
30.4 A
R
R SS
TT
N
N
L1 L2 L3 N PE
3N ~ 400V 50Hz + PE
Summary of Contents for Macro Series
Page 1: ...MA 5052 ENG 221220 GLUING SOLUTIONS ADHESIVE MELTER MACRO SERIES INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 32: ...FOCKE MELER GLUING SOLUTIONS 3 12 INSTALLATION This page is intentionally left blank ...
Page 58: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Page 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Page 71: ...ELECTRICAL DRAWINGS 7 1 MA 5052 ENG MACRO SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...