![Meler Macro Series Instruction Manual Download Page 65](http://html1.mh-extra.com/html/meler/macro-series/macro-series_instruction-manual_1767094065.webp)
MAINTENANCE
5-7
MA-5052-ENG
MACRO SERIES MELTER MANUAL
Recommended lubricants
Brand
Type of grease
IP
Telesia Compound A
SHELL
Tivela Compound A
MOBIL
Glygoyle Grease 00
Brand
Type of oil
KLÜBER
Klübersynth GH 6-220
SHELL
Tivela Oil S 220
MOBIL
Glygoyle 30
Thermostats maintenance
If one of the two existing thermostats is deactivated, follow these instructions
to reset them:
1. Remove the side plate, as shown in the image.
2. Lift the insulating blanket and locate the thermostats.
3. After the blanket has been lifted off the thermostats, identify the
thermostat that has been deactivated and press its corresponding
button to reset it (see Figure).
Summary of Contents for Macro Series
Page 1: ...MA 5052 ENG 221220 GLUING SOLUTIONS ADHESIVE MELTER MACRO SERIES INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 32: ...FOCKE MELER GLUING SOLUTIONS 3 12 INSTALLATION This page is intentionally left blank ...
Page 58: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Page 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Page 71: ...ELECTRICAL DRAWINGS 7 1 MA 5052 ENG MACRO SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...