GD-5510-01
Instructions Manual
4-5.Setting DRIVE CURRENT SELECT switch
Erroneous setting may cause burn on the
skin due to overheating of the motor.
Ensure correct setting.
DRIVE CURRENT is set up with the DRIVE I.SEL switch.
The switch is factory-set to [No.F].
(1) Set the DRIVE I.SEL switch No. to the setting specified in the table
"10-5. Applicable Motors".
● Relationship between the DRIVE I.SEL switch and DRIVE CURRENT.
(Factory setting)
(Factory setting)
C
D
E
8
9
A
B
4
5
6
7
0
1
2
3
0.44
0.48
0.51
0.54
0.58
0.61
0.64
0.68
switch No.
MOTOR SEL switch
switch1:ON
[5L]setting
F
A/phase
0.17
0.20
0.24
0.27
0.31
0.34
0.37
0.41
switch No.
A/phase
MOTOR SEL switch
switch1:OFF
[10L]setting
0
1
0.34
0.40
2
3
0.47
0.54
4
5
0.61
0.67
6
7
0.74
0.81
8
9
0.88
0.95
A
B
1.01
1.08
C
D
1.15
1.21
E
F
1.28
1.35
I