Instructions Manual
4-3.Setting HOLD CURRENT ADJUSTMENT trimmer
A high setting value may cause burn on the
skin due to overheating of the motor.
Do not select a high value beyond the
required.
HOLD CURRENT is set up with the HOLD I.ADJ trimmer.
The ratio of HOLD CURRENT to DRIVE CURRENT can be selected.
The trimmer is factory-set to approx. 40%.
(1)
Set the gauge of the trimmer to the required value.
●Relationship between the trimmer scales and HOLD CURRENT.
HOLD CURRENT
DRIVE CURRENT
Ratio of HOLD CURRENT (typical)
Trimmer
Scale of the trimmer
● HOLD CURRENT changes relative to DRIVE CURRENT setting.
The ratio of HOLD CURRENT of 100% represents the same as the setting for
DRIVE CURRENT.
● The greater the ratio of HOLD CURRENT grows, the more heat the motor
generates when is on holding-state.
● When the trimmer is set minimum, HOLD CURRENT is approx. 20% or less of
DRIVE CURRENT.
Ratio of HOLD CURRENT(%)=
×100
A I N
-15-
Summary of Contents for ADB-5F40
Page 30: ...Instructions Manual 10 2 I O Signal 1 Example Circuit Connection 30 ...
Page 35: ...Instructions Manual 10 4 Dimensions R1 Unit mm 35 ...
Page 38: ...Instructions Manual 38 ...
Page 39: ...Instructions Manual 39 ...
Page 40: ...Instructions Manual 40 ...
Page 41: ...Instructions Manual 41 ...
Page 42: ...Instructions Manual 42 ...