Instructions Manual
(4) Phase signal output(P.O)
① Output current
a. I
C
≦6mA, V
CE(sat)
<5V
b. I
C
≦2mA, V
CE(sat)
≦0.6V
V
CEO
≦30V
● In case of the excitation home position, the signal is output.
(photo-coupler ON)
② Timing chart
● P.O output timing (for 1/1 STEP)
CWP
CCWP
P.O
7.2°
(For a motor with the basic angle of 0.72°)
● P.O output time
1/1 STEP: once in 10 pulses
1/2 STEP: once in 20 pulses
1/4 STEP: once in 40 pulses
1/10 STEP: once in 100 pulses
1/20 STEP: once in 200 pulses
1
0
9
0
1
2
1
2
3
4
5
6
7
8
-33-