Instructions Manual
4-6.Setting HOLD SWITCHING TIME SELECT switch
DRIVE/HOLD CURRENT automatic switching time is set up
with the HOLD SWITCHING TIME SELECT switch.
The switch is factory-set to [DH1(150ms)].
(1) Set the DHT SEL [DH1/DH2].
4-7.Setting ROTATE CHARACTERISTIC SELECT switch
The switch is factory-set to [RC2].
●
By setting the switch to [RC1] the vibration of the motor in
a acceleration/deceleration drive may reduce.
●
Select it after evaluated characteristic with an actual device.
OFF
DH1(150ms)
DHT SEL
Hold Switching
Time
ON
DH2(15ms)
-18-