3 Description of the device

8

Symbols on the device

Manufacturer of the product

Date of manufacture of the product

Product serial number from the manufacturer

Article number of the product

The user manual includes important safety information. Failure to comply with these
instructions can result in injury and material damage.

Please read this user manual carefully before commissioning the device.

This symbol indicates that the marked area becomes hot during operation. Contact with
it during or shortly after operation can pose the danger of burns.

In affixing the CE mark, the manufacturer declares that this product fulfils the
corresponding EU requirements.

The device may not be disposed as domestic waste. The vendor is responsible for
appropriate disposal of the device - it must be delivered to the vendor to be disposed of.
MELAG devices are synonymous for long-term quality. When you eventually need to
decommission your MELAG device, we offer a special disposal service. Simply contact
your stockist.

Summary of Contents for Sterilisator 205

Page 1: ...lished MELAG as the world s leading manufacturer in the instrument treatment and hygiene field You our customer are justified in your demand for the best products quality and reliability Providing com...

Page 2: ......

Page 3: ...ir sterilizer on and off again 11 Opening and closing the door 12 Replacing the mount 12 6 Sterilization 13 Preparing the sterilization material 13 Loading the dry heat sterilizer 13 Information regar...

Page 4: ...legible damaged or lost obtain a new copy from MELAG State the device type and your address in an e mail The device type is specified on the type plate on the rear of the device Formatting rules Examp...

Page 5: ...quids may not be permitted to reach the interior of the device This could result in an electrical shock or short circuiting Preparation and sterilization n Do not place the objects to be sterilized on...

Page 6: ...ount 2 depending on the order Intended use This hot air sterilizer is intended for use in the cosmetics sector the cosmetic chiropody and the veterinary sector It was designed for the sterilization of...

Page 7: ...controller 3 Control lamp heater 4 Thermometer 5 Control lamp mains 6 On Off switch and time setting 7 Door handle 8 Door opens forwards 11 9 10 Fig 2 Rear view of the device 9 Fan 10 Type plate 11 Co...

Page 8: ...s symbol indicates that the marked area becomes hot during operation Contact with it during or shortly after operation can pose the danger of burns In affixing the CE mark the manufacturer declares th...

Page 9: ...l include a tray lifter The following loading versions are possible in devices with trays and standard tray cassettes of the follow ing sizes Tray W x H x D 19 x 2 x 36 cm Standard tray cassette W x H...

Page 10: ...alls especially flammable objects u Ensure sufficient ventilation Ensure sufficient clearance to the top for free removal of the warm air The device may not be used as an installation device and not b...

Page 11: ...control lamp will remain illuminated the control lamp for the heater will switch on and off until the time has elapsed The hot air sterilizer can be set to continuous operation In this case the hot a...

Page 12: ...sult in cooling and the objects not being sterilized for a sufficient time 1 Move the On Off switch to the 0 position to switch off 2 Move the door forwards to open 3 Move the door backwards to close...

Page 13: ...l on cellulose as this can result in a heat build up u Unwrapped sterilized equipment looses its sterility upon contact with the ambient air If you plan to store your instruments in a sterile fashion...

Page 14: ...erilization times table Selecting the sterilization times Do not exceed the specified loading quantities Use only trays and cartridges made of aluminium When needing to pack with foil use aluminium fo...

Page 15: ...he criteria specified below for the storage of sterilized equip ment u Comply with the maximum storage duration in accordance with the packaging type u Do not store the sterilized equipment in the rep...

Page 16: ...ng bio indicators thermocouples or maximum thermometers u Comply with the valid regional legal specifications u When performing the spore test using biological indicators the spore packets are to be c...

Page 17: ...d components When cleaning the sterilization chamber the mount for the load and the door seal comply with the following u Switch off the device before cleaning and disconnect the power plug from the s...

Page 18: ...set too low The temperature controller rotary knob was turned or set incorrectly when unpacking the device or because of incorrect handling e g during cleaning Set a higher temperature The temperature...

Page 19: ...220 240 V 50 60 Hz 110 V 50 60 Hz Maximum voltage range 207 253 V Maximum mains voltage supply variations 10 Electrical power 1100 W Device fuse 2 x 6 3 A T 12 5 A T 110 V Ambient conditions Installat...

Page 20: ...u can obtain the specified articles and an overview of further accessories from your stockist Article Art no Mount 1 60030 Mount 2 60040 Tray 02000 Standard tray cassette 00287 Tray lifter 28890 Lifte...

Page 21: ...Sterilisiergutes die geforderte Temperatur von 180 C zu erreichen DIN 58953 Standard sterilization sterile equipment supply Sterilization material Unsterile sterilizable material which is still to be...

Page 22: ...10 10829 Berlin Germany Email info melag com Web www melag com Original instructions Responsible for content MELAG Medizintechnik GmbH Co KG We reserve the right to technical alterations BA_Sterilisat...

Reviews: