2 Safety

5

2  Safety

When operating the device, comply with the following safety instructions as well as those
contained in subsequent chapters. Use the device only for the purpose specified in these
instructions. Failure to comply with the safety instructions can result in injury and/or damage to
the device.

Qualified personnel

n

As with the preceding instrument decontamination, the sterilization of instruments using this steam
sterilizer may only be carried out by competent personnel.

Set-up, installation and commissioning

n

The device should only be set-up, installed and commissioned by persons authorized by MELAG.

n

The device is not suitable for operation in explosive atmospheres.

n

Check the device for any damage suffered during transport after unpacking.

Power cable and power plug

n

Only the power cable included in the scope of delivery may be connected to the device.

n

The power cable may not be replaced by a cable determined to be insufficient.

Danger of short circuit

n

Liquids may not be permitted to reach the interior of the device. This could result in an electrical shock
or short circuiting.

Preparation and sterilization

n

Do not place the objects to be sterilized on material produced from cellulose (e.g., paper, paper tow-
els, staple fiber, bandage material, etc.); this material would produce excessive heat accumulation
which would prevent the required heat equalization in the sterilizer.

n

Observe the relevant standards and directives for the preparation of instruments.

n

In the case of obvious or suspected damage/defects, the device may not be operated further. In such
cases, the device has to be repaired.

Transport and storage

n

Store and transport the device in a frost-free environment.

n

Avoid strong shocks/vibrations.

Repair

n

Never open the device housing. Incorrect opening and repair can compromise electrical safety and
pose a danger to the user. The guarantee and warranty are forfeited as soon as the device is opened
by anyone other than a MELAG-authorized technician.

n

The device may only be repaired by the manufacturer or an agency which he has authorized to do so
(stockist or customer services).

n

Only original MELAG spare parts may be used.

Summary of Contents for Sterilisator 205

Page 1: ...lished MELAG as the world s leading manufacturer in the instrument treatment and hygiene field You our customer are justified in your demand for the best products quality and reliability Providing com...

Page 2: ......

Page 3: ...ir sterilizer on and off again 11 Opening and closing the door 12 Replacing the mount 12 6 Sterilization 13 Preparing the sterilization material 13 Loading the dry heat sterilizer 13 Information regar...

Page 4: ...legible damaged or lost obtain a new copy from MELAG State the device type and your address in an e mail The device type is specified on the type plate on the rear of the device Formatting rules Examp...

Page 5: ...quids may not be permitted to reach the interior of the device This could result in an electrical shock or short circuiting Preparation and sterilization n Do not place the objects to be sterilized on...

Page 6: ...ount 2 depending on the order Intended use This hot air sterilizer is intended for use in the cosmetics sector the cosmetic chiropody and the veterinary sector It was designed for the sterilization of...

Page 7: ...controller 3 Control lamp heater 4 Thermometer 5 Control lamp mains 6 On Off switch and time setting 7 Door handle 8 Door opens forwards 11 9 10 Fig 2 Rear view of the device 9 Fan 10 Type plate 11 Co...

Page 8: ...s symbol indicates that the marked area becomes hot during operation Contact with it during or shortly after operation can pose the danger of burns In affixing the CE mark the manufacturer declares th...

Page 9: ...l include a tray lifter The following loading versions are possible in devices with trays and standard tray cassettes of the follow ing sizes Tray W x H x D 19 x 2 x 36 cm Standard tray cassette W x H...

Page 10: ...alls especially flammable objects u Ensure sufficient ventilation Ensure sufficient clearance to the top for free removal of the warm air The device may not be used as an installation device and not b...

Page 11: ...control lamp will remain illuminated the control lamp for the heater will switch on and off until the time has elapsed The hot air sterilizer can be set to continuous operation In this case the hot a...

Page 12: ...sult in cooling and the objects not being sterilized for a sufficient time 1 Move the On Off switch to the 0 position to switch off 2 Move the door forwards to open 3 Move the door backwards to close...

Page 13: ...l on cellulose as this can result in a heat build up u Unwrapped sterilized equipment looses its sterility upon contact with the ambient air If you plan to store your instruments in a sterile fashion...

Page 14: ...erilization times table Selecting the sterilization times Do not exceed the specified loading quantities Use only trays and cartridges made of aluminium When needing to pack with foil use aluminium fo...

Page 15: ...he criteria specified below for the storage of sterilized equip ment u Comply with the maximum storage duration in accordance with the packaging type u Do not store the sterilized equipment in the rep...

Page 16: ...ng bio indicators thermocouples or maximum thermometers u Comply with the valid regional legal specifications u When performing the spore test using biological indicators the spore packets are to be c...

Page 17: ...d components When cleaning the sterilization chamber the mount for the load and the door seal comply with the following u Switch off the device before cleaning and disconnect the power plug from the s...

Page 18: ...set too low The temperature controller rotary knob was turned or set incorrectly when unpacking the device or because of incorrect handling e g during cleaning Set a higher temperature The temperature...

Page 19: ...220 240 V 50 60 Hz 110 V 50 60 Hz Maximum voltage range 207 253 V Maximum mains voltage supply variations 10 Electrical power 1100 W Device fuse 2 x 6 3 A T 12 5 A T 110 V Ambient conditions Installat...

Page 20: ...u can obtain the specified articles and an overview of further accessories from your stockist Article Art no Mount 1 60030 Mount 2 60040 Tray 02000 Standard tray cassette 00287 Tray lifter 28890 Lifte...

Page 21: ...Sterilisiergutes die geforderte Temperatur von 180 C zu erreichen DIN 58953 Standard sterilization sterile equipment supply Sterilization material Unsterile sterilizable material which is still to be...

Page 22: ...10 10829 Berlin Germany Email info melag com Web www melag com Original instructions Responsible for content MELAG Medizintechnik GmbH Co KG We reserve the right to technical alterations BA_Sterilisat...

Reviews: