Inaccurate measurement may result from the following: 

z

 

When the battery runs out: at this time, the 

  icon will continuously appear on LCD to 

remind you to replace the battery.       

                                                                                                               

 

z

 

When the measured distance is out of the specified range: the effective range is 2

~53

 

(0.6~16m).   

                                                                                                                               

 

z

 

When the calculated result is out of the specified range: at this time, an error message “Err” 
will be displayed on the lower line of the screen. 

 

 

z

 

When addition of different parameters (e.g. length plus area), the “+” will be ignored and the 
screen will keep the same read as the unit was operated before. 

z

 

When another ultrasonic source or high frequency noise is nearby: leave or shut down the 
noise resource when taking measurement. 

z

 

When barriers appear between the tool and the measured surface. 

z

 

When the measured surface is not smooth: the measured surface should be smooth, hard and 
of homogeneity. 

z

 

When the measuring environment is not good: the temperature and humidity will affect the 
accuracy of measurement, and take measurement under environment of no wind, and 
temperature of the unit should be same with temperature of the circumstance, especially for 
long distance measuring (between 40’ to 53’/ 12m to 16m), the relative humidity should be 
above 48%, and the size of measured surface should be at least 10ft. by 10ft./3m by 3m. 

z

 

When measuring, ultrasonic sensor aperture should straightly face to the measured surface. 

Cautions 

z

 

Handle with care and do not let the tool drop down. 

z

 

Do not disassemble the tool to avoid failure. 

z

 

Keep the tool dry and clean. 

z

 

Store the tool in the case when not in use. 

z

 

Avoid dust and water, which may stain the lens. 

z

 

Check battery regularly in case of its deterioration. 

z

 

Remove the battery when not in use for an extended period of time. 

 

8

Summary of Contents for KC-100B-1

Page 1: ...Manifold Electronic Gauge Model KC 100B 1 Operation Manual...

Page 2: ...ernational safety rule SAFETY INSTRUCTIONS Failure to follow the instructions listed below may cause personal injury z Read and understand all instructions prior to any operation z Do not remove any l...

Page 3: ...of upper line is the current measuring result and the data of lower line is the memory computing result D M Memory input key Input the length area or volume into memory E READ On read key Press this k...

Page 4: ...surface z Keep pressing the READ key and move the tool to get the dynamical readings and the measured distance will be displayed on upper portion of the screen z Press the SET key and the READ key to...

Page 5: ...n of the screen z Repeat the steps above can continue accumulation Addition using M memory z Press the M key to save the first measured result and the M will appear on the display z Press the READ key...

Page 6: ...will toggle back and forth between the length and width measurement on the upper portion of the screen Press SET key to clear the data on the portion of the screen then can begin the new calculation o...

Page 7: ...calculation of a room volume z The length character L on the screen will blink showing length measurement will be taking Press READ key to take length measurement the result will be displayed on upper...

Page 8: ...ar on LCD z Press SET key to clear the current displayed data then can begin the second time measurement and computation Follow step 1 to 3 under the volume section z After getting the calculated volu...

Page 9: ...z When the measured surface is not smooth the measured surface should be smooth hard and of homogeneity z When the measuring environment is not good the temperature and humidity will affect the accura...

Page 10: ...emperature 0 to 40 Operating humidity 30 70 Storage environment 20 60 85 w o battery Size 142mm 70mm 40mm Weight About 110g WARRANTY The product is warranted to be free from defects in materials and w...

Reviews: