background image

                                                                                                                                 

 

 

z

 

Press +/= key to enter the addition mode, and the “+” icon will appear on the display and at 

the same time, the result is displayed on the lower side of the display (press +/= key again to 

cancel the add operation);     

                                                                                                               

 

 

z

 

Press READ key again for second time measurement, the measured value is displayed on 
upper portion of the screen;         

                                                                                                                                 

 

z

 

Press +/= key again to display the sum on the lower portion of the screen;   

 

z

 

Repeat the steps above can continue accumulation. 

Addition (using M memory) 

z

 

Press the M key to save the first measured result, and the “M+” will appear on the display;               

 

                                                                                                                                 

 

z

 

Press the READ key for new measurement;             

                                                                                                               

 

 

z

 

Press the +/= key to enter the addition mode, and the “+” will appear on the display;   

           

 

z

 

Press the RM key to recall previous measurement for the addition (displayed on the bottom 
of the display), and at the same time, the “M+” icon disappears and the stored memories will 
be automatically eliminated;       

                                                                                                                                 

 

z

 

Press+/= key, the sum is shown on the lower portion of the screen.

 

 

 

 

                                                                                                                                 

 

 
 

 

4

Summary of Contents for KC-100B-1

Page 1: ...Manifold Electronic Gauge Model KC 100B 1 Operation Manual...

Page 2: ...ernational safety rule SAFETY INSTRUCTIONS Failure to follow the instructions listed below may cause personal injury z Read and understand all instructions prior to any operation z Do not remove any l...

Page 3: ...of upper line is the current measuring result and the data of lower line is the memory computing result D M Memory input key Input the length area or volume into memory E READ On read key Press this k...

Page 4: ...surface z Keep pressing the READ key and move the tool to get the dynamical readings and the measured distance will be displayed on upper portion of the screen z Press the SET key and the READ key to...

Page 5: ...n of the screen z Repeat the steps above can continue accumulation Addition using M memory z Press the M key to save the first measured result and the M will appear on the display z Press the READ key...

Page 6: ...will toggle back and forth between the length and width measurement on the upper portion of the screen Press SET key to clear the data on the portion of the screen then can begin the new calculation o...

Page 7: ...calculation of a room volume z The length character L on the screen will blink showing length measurement will be taking Press READ key to take length measurement the result will be displayed on upper...

Page 8: ...ar on LCD z Press SET key to clear the current displayed data then can begin the second time measurement and computation Follow step 1 to 3 under the volume section z After getting the calculated volu...

Page 9: ...z When the measured surface is not smooth the measured surface should be smooth hard and of homogeneity z When the measuring environment is not good the temperature and humidity will affect the accura...

Page 10: ...emperature 0 to 40 Operating humidity 30 70 Storage environment 20 60 85 w o battery Size 142mm 70mm 40mm Weight About 110g WARRANTY The product is warranted to be free from defects in materials and w...