About the MT90A 

5.1

 

Appearance 

 

No. 

Item 

Description 

GPS indicator (blue) 

Indicates GPS and battery status. For details, see the section 5.2 "Indicator." 

GSM indicator 

(green) 

Indicates GSM status. For details, see the section 5.2 "Indicator." 

Answer/Hang-up 

button 

 

Press the button to receive an incoming call. 

 

Press the button to terminate the call. 

 

Press and hold down the button for 2s to send a GPRS message to the server 

when no incoming call or conversation is received. In this way, the device will 

sound “BI” once and vibrate. 

SOS button 

 

Press and hold down the button for 2s in the case of emergency. The device 

will sound "BI" once and vibrate. The MT90A will also dial three authorized 

phone numbers in turn. It will stop dialing when one phone number answers. 

Meanwhile, the MT90A will send an SMS to the authorized phone number and 

send a GPRS message to the server if the GPRS function is enabled. 

 

Press the button to wake the device up if the device is in sleep mode. 

Microphone 

It will run automatically when the listen-in and call functions are used. 

Loudspeaker 

It will run automatically when the call function is used. 

Power on/off 

button 

 

Press and hold down the button for 2s to turn on the MT90A. 

 

Press and hold down the button for 2s to turn off the MT90A. 

 

Press the button to wake the MT90A up from sleep mode. The power indicator 

will blink for 10s. 

Micro USB port 

Used for charging, connecting a computer for parameter settings, and upgrading 

software. 

/GPS Log 

button 

 

Press the button to turn up the volume. 

 

Press and hold down the button for 2s to start hands-free conversation. 

Summary of Contents for MT90A

Page 1: ...MEITRACK MT90A User Guide MEITRACK MT90A User Guide...

Page 2: ...Group All rights reserved 2 Change History File Name MEITRACK MT90A User Guide Created By Renny Lee Project MT90A Creation Date Update Date 2011 05 16 2014 09 02 Subproject User Guide Total Pages 15...

Page 3: ...y Alarm 4 3 1 3 Other Functions 4 3 2 Specifications 5 4 MT90A and Accessories 5 5 About the MT90A 6 5 1 Appearance 6 5 2 Indicator 7 6 First Use 8 7 Quick Operation Command 9 7 1 Real time Location T...

Page 4: ...onomic losses personal injuries and loss of assets and property caused by the use inability or illegality to use the product or documentation 2 Product Overview The MT90A a personal tracking device is...

Page 5: ...ption 60 mA standby current and 5 mA deep sleep Operating temperature 20 C to 55 C Humidity 5 to 95 Working hour 240 hours in power saving mode and 14 hours in normal mode Indicator 2 indicators showi...

Page 6: ...so dial three authorized phone numbers in turn It will stop dialing when one phone number answers Meanwhile the MT90A will send an SMS to the authorized phone number and send a GPRS message to the ser...

Page 7: ...ault GPRS message interval is 10 minutes Press and hold down the button for 2s again when the buzzer sounds BI twice the GPRS function will be disabled automatically Note To avoid misoperations you ca...

Page 8: ...ote Ensure that the SIM card password lock is closed and the SIM card has sufficient balance and has subscribed the call ID service If you want to use the GPRS function learn about the SIM card GPRS c...

Page 9: ...ter into a power outlet Note Incorrect connection may cause serious damages to the device Any damage caused by misuse is not covered in the warranty Attach a lanyard Slide the lanyard through the slot...

Page 10: ...e V The GPS is invalid A Valid V Invalid 16 Indicates the GSM signal strength Value 1 32 The larger the value is the stronger the signal is If the value is greater than 12 GPRS reaches the normal leve...

Page 11: ...ntains a maximum of 16 bytes If no function number is set leave Function number blank default value Function number 1 Set the phone number to the SOS number When you dial the tracker the tracker repli...

Page 12: ...ers send 0000 A72 7 4 Smart Sleep A73 This command is used to enable the sleep mode function prolonging standby time to 240 hours In this mode the recorder scheduled tracking and location tracking fun...

Page 13: ...d to enable the man down alarm function An alarm will be generated in case of falling SMS text 0000 A29 Switch Time Grade Responding IMEI A29 OK Note 1 Switch indicates the man down alarm detection sw...

Page 14: ...User name IMEI number Password 0000 default You can perform the following operations on the GPS platform Query a location at certain time Query the trace Add favorites View various reports For more i...

Page 15: ...ndicates that this product and its accessories such as chargers batteries and the USB cable cannot be disposed of with other household wastes when they reach the end of their life If batteries are not...

Reviews: