Swiping an RFID card: 

 

 
Note: In the locking or unlocking state, if you swipe an unauthorized RFID card, the buzzer will beep twice. If you 
swipe an authorized RFID card, the buzzer will beep once. After the K211G is unlocked, if you do not pull out the lock 
rope within one minute, the K211G will be locked automatically. 
 

Locking or Unlocking by Commands 

Command 

Description 

How to Send 

D82 

This command is used to lock or 
unlock the K211G. 

Send the command by SMS or GPRS. For details about 
the SMS command format, see the section 6.6.5 
"Locking or Unlocking the K211G – D82." 

D83 

This command is used to select a 
locking method: auto locking or 
locking by swiping RFID cards. 

Send the command by SMS or GPRS. For details about 
the SMS command format, see the section  6.6.6 
"Selecting a Locking Method – D83." 

 

2.1.3

 

Dual SIM Cards 

The K211G can be installed with two Micro SIM cards and supports the dual SIM single standby mode. The device will 
automatically select a SIM card to register the network. SIM1 (on the right) will be selected by default. If SIM1 fails 
to register the network, SIM2 (on the left) will be selected to do this. (Please ensure that at least one SIM card can 
be used normally.) 

 

Summary of Contents for K211G

Page 1: ...MEITRACK K211G GPS Smart Lock User Guide MEITRACK K211G GPS Smart Lock User Guide Applicable Model K211G...

Page 2: ...Copyright 2018 Meitrack Group All rights reserved 2 Change History File Name MEITRACK K211G GPS Smart Lock User Guide Project K211G Creation Date 2018 11 27 Subproject User Guide Total Pages 16 Versio...

Page 3: ...SIM Card 9 6 2 Turning on the K211G 10 6 3 LED Indicator 10 6 4 Device Configuration 11 6 4 1 Installing the USB Driver 11 6 4 2 Configuring Device Parameters by Meitrack Manager 11 6 5 Binding or Unb...

Page 4: ...r long standby time There is no button on the outer case of the device and the IP67 water resistance rating makes the device withstand harsh environments It is specially designed for door lock managem...

Page 5: ...e disabled Report data at the preset interval 2 1 2 Locking or Unlocking the K211G Locking or Unlocking by Swiping RFID Cards The function is used to lock or unlock the K211G by swiping authorized RFI...

Page 6: ...e command by SMS or GPRS For details about the SMS command format see the section 6 6 5 Locking or Unlocking the K211G D82 D83 This command is used to select a locking method auto locking or locking b...

Page 7: ...open alert An alert will be generated when the K211G s outer case is removed or the back cover is opened Lock tamper alert An alert will be generated when the lock rope is cut off T399G disconnected a...

Page 8: ...end this command by SMS or MS03 platform 4 Product Specifications Item Description Dimension 112 mm x 195 mm x 37 mm Lock rope length 350 mm The length can be customized as needed Weight 800g Power su...

Page 9: ...frequency 125 KHz Memory 8 MB SIM card installation Flip the card slot cover to install Micro SIM cards dual SIM cards 5 Main Device and Accessories 6 First Use 6 1 Installing a SIM Card Remove the f...

Page 10: ...to the T399G Steady on The K211G is unlocked Blink fast 0 2 seconds on and 4 8 seconds off The K211G is connected to the T399G GPS LED Indicator Blue Blink fast once every 0 1 seconds The K211G is be...

Page 11: ...Installing the USB Driver Install the USB driver on a computer with 64 bit Windows system After the installation is finished connect the K211G to the computer by USB cable If Prolific USB to Serial Co...

Page 12: ...nager User Guide 6 5 Binding or Unbinding the T399G 6 5 1 Binding the T399G To make the K211G and T399G communicate with each other via LoRa bind the two devices An IMEI number is the default binding...

Page 13: ...1 Setting GPRS Parameters A21 SMS Sending 0000 A21 Connection mode IP address Port APN APN user name APN password SMS Reply IMEI A21 OK Description Connection mode 0 function disabled Connection mode...

Page 14: ...minute SMS Reply B35 OK Description The default time zone of the device is GMT 0 You can run the B35 command to change the time zone of an SMS report to the local time zone The time zone of an SMS rep...

Page 15: ...PS Tracking System MS03 User Guide chapter 4 Getting Started The MS03 supports the following functions Track by time interval or distance Query historical trips Set polygonal geo fences Bind driver an...

Page 16: ...MEITRACK K211G GPS Smart Lock User Guide Copyright 2018 Meitrack Group All rights reserved 16 8 Device Installation If you have any questions do not hesitate to email us at info meitrack com...