background image

User’s manual 
Primor 2000 / Level 15

© Carl Wittkopp GmbH - Errors and omissions excepted

Content

1 General instructions

 __________________________________________________2

1.1 Liability notes _________________________________________________________2

1.2 Operating notes _______________________________________________________2

1.3 Notes on safety ________________________________________________________2

2 Visual and acoustic signals

____________________________________________3

3 Input units

 ____________________________________________________________3

4 Operating the lock

 ____________________________________________________3

4.1 Opening _____________________________________________________________3

4.1.1 Opening with alarmcode (silent alarm) _________________________________4

4.2 Locking ______________________________________________________________4

5 Programming the lock

 ________________________________________________5

5.1 Master and user codes _________________________________________________5

5.1.1 Programming a user code _____________________________________________5

5.1.2 Changing the master or user code _____________________________________5

5.1.3 Deleting a user ______________________________________________________5

5.2 Time delay and opening window_________________________________________6

5.2.1 Adjusting the time delay and opening window ___________________________6

5.2.2 Opening with activated time delay and opening window __________________7

5.2.3 Deleting the time delay _______________________________________________7

5.2.4 Opening with the instant opening code _________________________________8

6 Operation blocking

 ___________________________________________________8

7 Overview users

 _______________________________________________________8

8 Testing the system

 ____________________________________________________9

9 Power supply and battery change

 _____________________________________9

Rel. 1.6 

01.02.2016 

Bedienungsanleitung Nr. 9999-116-1

Summary of Contents for Primor 2000 / Level 15

Page 1: ..._____________________________________5 5 1 Master and user codes__________________________________________________5 5 1 1 Programming a user code______________________________________________5 5 1 2 C...

Page 2: ...switch off Re enter the code and repeat the process When the time between touching keys exceeds 10 seconds the process of programming and entering is deleted The old code or programmes stay valid Eve...

Page 3: ...erating the lock 4 1 Opening 1 Enter the 7 digit code e g master code 1234567 2 Turn the input unit the lever clockwise within 3 seconds into opening position The lock is opened After 4 consecutive wr...

Page 4: ...f the code Usually this is 1 If the result becomes double digit only the last number is taken e g 9 1 10 enter only 0 The lock opens normally after entering the alarmcode Simultaneously a relay is tri...

Page 5: ...med user 9 for instant opening code if it has not been programmed yet can only be pro grammed during the release window 5 1 3 Deleting a user programme 3 The master is able to delete a user but not vi...

Page 6: ...20 minutes 20 6 Re enter the opening window e g 10 minutes 10 The time delay can be increased at any time It can be reduced only during the opening window 5 2 Time delay and opening window Only the m...

Page 7: ...indow 01 8 Delete the time delay again 00 9 Delete the opening window again 01 5 2 2 Opening with activated time delay and opening window 1 Enter your 7 digit code e g mastercode 1234567 2 Wait until...

Page 8: ...me Have user codes been disabled the lock can be opened only with the master code 1 Press and hold the key 2 until the red LED flashes permanently 2 2 Enter your 7 digit master code e g 123456 5 2 4 O...

Page 9: ...ce 123 90 9 Power supply and battery change The lock is power supplied by one 9 V block battery alkaline no rechargeable batteries When battery voltage is insufficient after entering the code a warnin...

Page 10: ...10 Primor 2000 Level 15...