INSTRUCTION MANUAL
40
Plate power limit
The plate's total power level is calculated whenever the user attempts to increase the power. If this total power level
is in excess of the plate's pre-set power limit, the power increase is not permitted, an error beep sounds and the
display shows "r" for 3 seconds.
Blocking
press the block sensor (key) for 3 seconds to activate or deactivate the blocking function. If the key symbol is shown,
the hob is not blocked.
.
2.8. TIME LIMIT IN OPERATION
For safety reasons, the zone deactivates automatically when a certain maximum operating time is exceeded.
The maximum operating time depends on the level selected for the zone:
level 1-10 hours
level 4-10 hours
level 7-10 hours
level 2-10 hours
level 5-10 hours
level 8-10 hours
level 3-10 hours
level 6-10 hours
level 9-3 hours
2.9. TIMER OPERATION
The time value can be selected between 1 and 99 minutes, and it is possible to set the time for a zone at any power
level (0 .. 9); the user can only select one zone at a time for the timer function.
Activate Timer:
Press the timer sensor (+) or (-). A noise sounds and the display shows a 00 "time" symbol. The displays show a
flashing "1", indicating that the timer has been activate for the zone in question.