4 Technical Specifications LANTIME Chassis

Housing

19" multipac housing, 1U

Housing material

sheet steel

——————————————————————————-

Temperature range

Operation

0 ... 50

C (0 ... 122

F)

Storage

-20 ... 70

C (-4 ... 158

F)

——————————————————————————-

Relative humidity

Operation

max. 85 % (non-condensing) at 30

C

——————————————————————————-

Maximum altitude

Operation

max. 2000 m / 6562 ft (above sea level)

——————————————————————————-

Acoustics

0 dB (A)

IP protection class

IP20

14

Date: 3rd September 2019

LANTIME M300/RDT

Summary of Contents for LANTIME M300/RDT

Page 1: ...TECHNICAL REFERENCE LANTIME M300 RDT NTP Time Server 3rd September 2019 Meinberg Radio Clocks GmbH Co KG...

Page 2: ......

Page 3: ...atteries 10 2 8 Cleaning and Care 11 2 9 Prevention of ESD Damage 11 2 10 Return of Electrical and Electronic Equipment 12 3 Global Information LANTIME M300 RDT 13 4 Technical Specifications LANTIME C...

Page 4: ...Funkuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Internet https www meinbergglobal com Mail info meinberg de Date 2019 09 03 LANTIME M300 R...

Page 5: ...only continue if you have understood and fulfilled all requirements In this documentation dangers and indications are classified and illustrated as follows DANGER The signal word indicates an imminent...

Page 6: ...ines elektrischen Schlages Caution risk of electric shock IEC 60417 5041 Vorsicht hei e Oberfl che Caution hot surface IEC 60417 6056 Vorsicht Gef hrlich sich bewegende Teile Caution moving fan blades...

Page 7: ...ed for the purpose described in this manual In particular the given limits of the device must be observed The safety of the installation in which the unit is integrated is the responsibility of the in...

Page 8: ...Installation in an air conditioned control cabinet required Transport Unpacking Installation If the unit is brought into the operating room from a cold environment condensation may occur wait until t...

Page 9: ...operly and are undamaged Pay particular attention to the facts that the cables do not have kinks or that they are not too short around corners and no objects are placed on the cables Also make sure th...

Page 10: ...e mains socket on the appliance or the mains socket of the house installation is freely accessible to the user so that the mains cable can be pulled out of the socket in case of emergency Outside the...

Page 11: ...onductor via the protective earth connection terminal If an external earth connection is provided on the housing it must be connected to the equipotential bonding rail grounding rail The mounting part...

Page 12: ...led and when the doors are closed cooling fire protection shielding against electrical magnetic and electromagnetic fields Switch off in fault service case By switching off the devices are not disconn...

Page 13: ...for the user and result in a loss of warranty as well as an exclusion of liability Danger due to moving parts keep away from moving parts Device parts can become very hot during operation Do not touc...

Page 14: ...ction Prepare removal and installation of assemblies Unload yourself for example by touching a grounded object before touching assemblies Ensure that you wear a grounding strap on the wrist when worki...

Page 15: ...product symbol on the left indicates that this electronic product must not be disposed of in domestic waste Return and Collection Systems For returning your old equipment please use the country specif...

Page 16: ...ernal reference as well as a combination of these references hybrid system External references are also possible The LANTIME system is a set of equipment composed of an integrated receiver a single bo...

Page 17: ...al sheet steel Temperature range Operation 0 50 C 0 122 F Storage 20 70 C 4 158 F Relative humidity Operation max 85 non condensing at 30 C Maximum altitude Operation max 2000 m 6562 ft above sea leve...

Page 18: ...mm 17 51 inch 304 mm 11 98 inch 288 mm 11 32 inch External Ground Connection on the Housing This connector must be wired to an equipotential bonding bar earthing bar Connection is possible on both si...

Page 19: ...ESC several times The main menu reflects some of the main parameters of the time server First line dis plays the status of the Reference Clock The text RDT serial Refclock might be replaced by RDT ex...

Page 20: ...it is possible to configure parameters with the command line interface You have to use a NULL MODEM cable connecting to your PC or Laptop com puter You can use e g the standard Hyperterminal program s...

Page 21: ...eat Emission Etherm 108 00 kJ h 102 37 BTU h O I 100 240 V 50 60 Hz WARNING This equipment is operated at a hazardous voltage Danger to life due to electrical shock Only qualified personnel electricia...

Page 22: ...e SUB D connector Pin 1 Refclock 0 The PPS In level can either be TTL or RS232 Assignment Pin 1 PPS in Refclock 0 Pin 2 RxD Receive Data input Pin 3 TxD Transmit Data output Pin 5 GND ground Refclock...

Page 23: ...on type BNC female Cable shielded coax line PPS In 6 4 10 100Base T Network Port IEEE 803 2 Output signal 100Base T Data transmission speed 10 100 MBit s Connection type 8P8C RJ45 Cable Copper twisted...

Page 24: ...rcury hexavalent chromium polybrominated biphenyls PBBs and polybrominated diphenyl ethers PBDEs above the legal threshold WEEE status of the product This product is handled as a B2B Business to Busi...

Page 25: ...en bereinstimmt to which this declaration relates is in conformity with the following standards and provisions of the directives RED Richtlinie ETSI EN 303 413 V1 1 1 2017 06 RED Directive 2014 53 EU...

Reviews: