Technical Specifications Power Supply Unit PULS AP336.505
INPUT
VOLTAGE:
105 ... 300V DC, max. 0.7A
85 ... 265V AC, 47... 63Hz, max. 1.5A
FUSE:
electronic
OUTPUT
VOLTAGES:
V
out
1:
5.15V / 2A
V
out
2:
+12V / 1A
V
out
3:
-12V / 1A
Minimum load of the 5V output when control accuracy of the
12V outputs should be smaller than 4%: 100mA
TOTAL
SAVE LOAD:
max. 35Watt
TYPE OF
CONNECTOR:
male connector according to DIN 41612, type H15, pre-mating
protective contact
MOUNTING
FRAME:
19" module 3U / 9HP (128 mm high x 45 mm wide), according
to DIN 41494, part 5
Product safety according to EN 60950
Front Panel and Rear Connector Pin Assignments
d z
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
GND 1
+Vout 1
+Vout 1
GND 1
GND 2/3
NC
NC
Pfl
Vout 2
Vout 3
GND 2/3
NC
N (GNDin)
L (Vin)
PE
male connector according to DIN41612, type H15,
pre-mating protective contact
Summary of Contents for GPS167TGP
Page 1: ...Technical Information Operating Instructions GPS167TGP AP336 505...
Page 29: ...29 Menu Quick Reference for progr Pulse CLR ACK CLR ACK INC MODE AKTIV MENU NEXT NEXT...
Page 49: ...49 AFNOR Standard Format...
Page 56: ...56 Menu Quick Reference GPS167 CLR ACK CLR ACK MENU NEXT...
Page 57: ...57 Technical appendix...
Page 59: ...59 Rear panel view GPS167TGP 1 14 13 25 1 14 13 25 Made in Germany...
Page 62: ...GP S 1 6 7 _ TGP E 0 5 0 5 0 6...