SETUP POUT X
(optional)
This menu is used for configuration of the pulse outputs. There are three pulse outputs
available (POUT 1-3).
Mode
This field selects the mode of operation of an output. Possible modes are POUT OFF,
POUT TIMER, SINGLE PULSE, CYCLIC PULSE, PPS, PPM and PPH.
Timer mode
If Timer mode is selected, a window as shown above is displayed. The switching plan
is assigned per day. Three turn-on and turn-off times are programmable for each
output. If a switching time has to be configured, only the turn-on and turn-off time
must be programmed. Thus the example shows switching times from 10.50 to 11.00,
13.00 to 14.00 and 23.45 to 23.50. A turn-off time earlier than the turn-off time would
cause the output to be enabled over midnight. For example a program
'On Time'
10.45.00,
'Off Time'
9.30.00 would cause an active ouput from 10.45 to 9.30 (the
next day!). If one or more of the three switching times are unused just enter the same
time into the fields
'On Time'
and
'Off Time'
.
In this case the switch time does not
affect the output.
Summary of Contents for GPS167TGP
Page 1: ...Technical Information Operating Instructions GPS167TGP AP336 505...
Page 29: ...29 Menu Quick Reference for progr Pulse CLR ACK CLR ACK INC MODE AKTIV MENU NEXT NEXT...
Page 49: ...49 AFNOR Standard Format...
Page 56: ...56 Menu Quick Reference GPS167 CLR ACK CLR ACK MENU NEXT...
Page 57: ...57 Technical appendix...
Page 59: ...59 Rear panel view GPS167TGP 1 14 13 25 1 14 13 25 Made in Germany...
Page 62: ...GP S 1 6 7 _ TGP E 0 5 0 5 0 6...