![Meinberg GPS167TGP Operating Instructions Manual Download Page 26](http://html1.mh-extra.com/html/meinberg/gps167tgp/gps167tgp_operating-instructions-manual_1766132026.webp)
26
SETUP SERIAL STRING TYPE
This topic is used to select one of several different types of serial time strings or the
capture string for each serial port. Default parameters are:
COM0:
Meinberg
COM2:
Meinberg
COM1:
Capture
COM3:
Meinberg
The following time strings can be selected:
-
Meinberg Standard String
-
GPS167 Capture String
-
SAT String
-
UNI-Erlangen String
-
NMEA String (RMC)
-
SPA String
-
Computime String
Other technical details are described at the end of this manual.
SETUP SERIAL STRING MODE
This menu lets the user select the serial ports´ mode of operation. The possible modes
depend on the selected output string. If a time string is selected it can be sent
automatically "Per Second", "Per Minute" or only "On Request" (sending an ASCII
"
?
" to the clock). If the capture string is selected it can be sent automatically when a
trigger event occurs ("String Auto") or only "On Request" (sending an ASCII "
?
" to
the clock). If capture message "On Request" is selected it is the user´s responsibility to
read out the capture buffer by sending an ASCII "
?
" to COMx or by the binary
protocol via COM0 in order to avoid a buffer-overrun and the loss of new trigger
events.
Summary of Contents for GPS167TGP
Page 1: ...Technical Information Operating Instructions GPS167TGP AP336 505...
Page 29: ...29 Menu Quick Reference for progr Pulse CLR ACK CLR ACK INC MODE AKTIV MENU NEXT NEXT...
Page 49: ...49 AFNOR Standard Format...
Page 56: ...56 Menu Quick Reference GPS167 CLR ACK CLR ACK MENU NEXT...
Page 57: ...57 Technical appendix...
Page 59: ...59 Rear panel view GPS167TGP 1 14 13 25 1 14 13 25 Made in Germany...
Page 62: ...GP S 1 6 7 _ TGP E 0 5 0 5 0 6...