code unequal to '0' is returned. The cause of the error can be
determined with the functions for error handling.
me9000mioCntGetIrqCount
✎
Description
ME-9000
ME-9100
ME-9300
ME-90 PC/104-Plus
✔
–
–
✔
This function determines the number of interrupts from the
counter. Condition: interrupt operation enabled by function
me9000mioCntConfig
. By call up the value of parameter Count it
is possible to determine relative to a previous call up whether an
interrupt occurred or not.
Definitions
VC: me9000mioCntGetIrqCount (unsigned int uiBoardNumber,
unsigned long *pulCount);
VB: me9000mioVB_…(see
me9000mio.bas
)
➔
Parameters
<
BoardNumber>
Number of the board to be accessed of type ME-9000.
<Count>
Total number of interrupts from the counter (IRQ-CNT).
‹
Return value
If the function is successfully executed, a '0'
ME9000MIO_NO_ERROR) is returned. If an error occurs, an error
code unequal to '0' is returned. The cause of the error can be
determined with the functions for error handling.