- to PC ground: 500
V
- between the ports (only „p“-models): 500
V
Multi-I/O Pins (ME-9000, ME-90 PC/104-Plus)
Number
8
-
bit bidirectional
Type
TTL ports
Interrupt
IRQ-DIO (must be enabled)
Output level
(Vcc = 5
V±10
%)
U
OL
: max. 0,55
V at 6
mA
U
OH
: min. 2,4
V at -2
mA
Input level
(Vcc = 5
V±10
%)
U
IL
: -0,5 < 0,8
V
U
IH
: 2,0
V < 6,0
V
Reference to GND
PC ground (GND_PC)
Counter (ME-9000, ME-90 PC/104-Plus)
Number
1 x 16
bit
Type
down-counter
Modes
„Single-Shot“ or „Retrigger“
Clock source
internal/external
Internal Oscillator
crystal oscillator (14,7456
MHz/100
ppm)
Ext. clock input
TMRCK
Interrupt
IRQ-CNT (must be enabled)
Reference to GND
PC-ground (GND_PC)
General Information
Power consumption
typ. 2,3
A at +5
V
Max. load of VCC on the
customer design area
(DA) resp. ST2 of the ME-
9000:
max. 300
mA @ VCC (+5
V resp. +3,3
V)
Max. load of VCC via ST3
of the ME-90 PC/104-
Plus:
max. 300
mA @ VCC (+5
V)
Physical size (without
mounting bracket and
connectors)
ME-9000 PCIe: 124 x 99
mm
ME-9000 PCI: 124 x 99
mm ME-9100 PCI:
136 x 99
mm ME-9300 PCI: 129 x 99
mm
ME-90 PC/104-Plus: 90 x 96
mm
CompactPCI models: 3U CompactPCI
Summary of Contents for ME-90 Series
Page 30: ...3 2 Block Diagram ME 9100 2 4 or 8 RS 232 and or RS 422 485 ports depending on version...
Page 31: ...3 3 Block Diagram ME 9300 8 or 16 RS 232 ports depending on version...
Page 35: ......
Page 36: ......
Page 37: ......
Page 38: ......
Page 39: ...3 5 2 ME 9100 PCI...
Page 40: ...3 5 3 ME 9100 CompactPCI...
Page 68: ......
Page 105: ...B2 ME 9000 9100 RS 422 485 see note on page 111...
Page 112: ...B8 9 pin male connector ME 90 PC 104 Plus B9 8 pin RJ 45 female connectors...
Page 113: ...B10 Null modem cable see note on page 111 not for ME 90 PC 104 Plus...