Total accuracy
„With electrical isolation“
max. ±20 mV
„With island channels“
max. ±10
mV
Operation modes
„Single“, „Streaming“
Trigger modes
software start, ext. digital trigger,
synchronous start (software/external)
External trigger edges
rising, falling, any
Timer-Controlled Output (ME-6100/6300, channel 0…3)
Channels
0…3 (independent of one other)
D/A-FIFOs
8 k values per channel
Sample-Rate
max. 500 kS/s
D/A-Timer
programmable from 2
μ
s up to 130 s in
steps of 30.30 ns
External Trigger (channel 0…3)
Voltage level
typ. 5
V
Input current I
F
7.5 mA
≤
I
F
≤
10
mA
Reference to ground
ground (GND_ )
Delay time
max. 80 ns
Electrical Isolation, Island Channels (optional)
Over-voltage protection
max. 500 V
Output Buffer „U-Plus“ (channel number 8)
Output line l
U
OUT
_8
Voltage range
0…50 V
Output current
max. 20 mA
Offset error
typ.±5 mV; max.± 20 mV
Gain error
±0,16 %
Settling time
max. 25
μ
s at full-scale (0 50 V)
with 20