Meikyo Electric WATCH BOOT RPC-M5C-EA User Manual Download Page 10

 

10

3. Monitoring Status Display: Indicates status of power supply, active, and temperature monitoring   

Device Information 

Device  name:  The  name  assigned  in  the  Basic  Settings  is 

displayed here 

Location:  The  location  entered  in  the  Basic  Settings  is 

displayed here.   
Outlet

 

Monitoring Condition 

AC outlet monitoring Condition   
Outlet Name: The outlet name specified in the Basic settings is 

displayed. 

Status: Displays the outlet’s current judgement status. 

Monitoring/Normal/Recovering/Abnormal 

Execute: Number of PING monitoring executed 
Power: Shows whether the outlet is ON or OFF. 

Judgement Condition 

Trans: Number of PINGs transmitted 
NoAns: Number of PINGs with no reply   
Target: Number of devices subject to PING monitoring 
Action: Specified action monitoring 
(No Action/Log only/Reboot)   

Monitoring Condition 
Cond: Response status with IP address 
NoRes: Number of no response to destination address 
PING Response time   
ResTime: Response time from   
Heartbeat Status 
  Motion: Specified outlet operation 
  Execution: Number of executions of specified operation 
  Packet: Current heartbeat packet status 

Mail Server Status: Number of failed POP server connection:       
Number of failed connections   
Click the refresh icon on the upper right part of the screen to update to the most current information. 

 
 

4. Event log: Displays the event history. 

Previous page: Display the previous page.   
Next page: Display the next page. 
Top page: The first page is displayed. 
Last page: The last page is displayed. 
Text page: Display the event log as text on the web browser. 
All Log Clear: Clear the log. (This process cannot be undone) 

Maximum 100 items are displayed on one page. Maximum   
1,000 items of the log are displayed on 10 pages.   

Click  the  refresh  icon  on  the  upper  right  part  of  the  screen  to 
update to the most current information. 
 
 

Summary of Contents for WATCH BOOT RPC-M5C-EA

Page 1: ...indicate important messages for the safe use of this product The meaning of each symbol is as follows Typical alert symbols and signal words Warning Indicates items that may result in death or serious injury of a person if the product is improperly handled Caution Indicates items that may result in injury of a person or property damage if the product is improperly handled Property damage shall mea...

Page 2: ...ceeding 12 A Fire or malfunctioning may result Max 12 A Never connect multiple devices to a single outlet The product must be directly connected to the power outlet on the wall Do not use the unit with power strips or extension cords Fire or malfunctioning may result Connection of multiple devices prohibited Handle the power cable with care Do not place heavy objects on the power cable with a heav...

Page 3: ...or use a combustible article such as a hair spray above or near the unit The unit may catch fire from a spark from a switch contact Combustible article is prohibited Never touch the unit and the power plug during thunderstorms Electrical shock may result Although each unit comes equipped with a lightning protection circuit note that its effect is limited unless the FG terminal is properly grounded...

Page 4: ... surface may result Cleaning of the electrical contacts must be made using a dry soft cloth after unplugging power cables to avoid damage to the unit The power cable and all other cables connected to the outlets or connectors of this unit must be unplugged before cleaning Electrical shock or malfunction may result Unplug power cables Never place the unit in a humid or dusty place Never place the u...

Page 5: ...e to dropping or tilting of the product Avoid a place not secured Never place the unit close to a radio or TV set The unit may interrupt wireless signals when placed near a radio or TV set Avoid a place close to radio or TV set Data saving Before transmitting data take appropriate steps to backup data when possible Data may be lost due to faults in the circuit or in the unit Make a backup Never pl...

Page 6: ...quipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from ...

Page 7: ...ower outlet 2 DIP Switch Normal operation All switches OFF UP Initial setting DIP switch 3 ON Factory Reset Switches 1 and 3 ON Note When moving the DIP switch unplug all devices from AC outlets After setting the DIP switches correctly press the RESET button 3 Steps for Initializing Move the DIP switches 1 and 3 on the front panel to ON and insert the power plug When power is supplied LINK lamp on...

Page 8: ...nnect the Ethernet cable to the Ethernet socket on the front panel 3 Connect the supplied power cable to theAC inlet and power outlet Caution Only use the supplied power cable set Section 3 Factory Reset Please use Internet Explorer version 11 or later Initial Settings is a useful function when the IP address settings for the device is forgotten or misplaced To assign a static IP address to allow ...

Page 9: ...assword magic default 3 The Simple Information Display screen will appear 2 Simple Information Display Indicates device name and power supply status Attention Simple Information Display screen only indicates the current status of the unit Control or configuration through this screen is impossible Device name The name assigned in the Basic Settings is displayed here Location The location entered in...

Page 10: ...Condition Cond Response status with IP address NoRes Number of no response to destination address PING Response time ResTime Response time from Heartbeat Status Motion Specified outlet operation Execution Number of executions of specified operation Packet Current heartbeat packet status Mail Server Status Number of failed POP server connection Number of failed connections Click the refresh icon on...

Page 11: ...Outlet Information Device name The name assigned in the Basic Settings is displayed here Location The location entered in the Basic Settings is displayed here Virtual Outlets WOL Displays the description of respective virtual outlet Individual virtual outlet WOL Send Sends magic packets to respective virtual outlet All virtual outlets WOL Send Sends magic packets to all virtual outlets A virtual o...

Page 12: ...t delay ON delay and start delay seconds Set reboot time for all outlets Outlet Link setting Outlet Link Assign outlets to link together Front Panel Setting LED Status by LED Set to Enabled or Disabled 9 Time setting Synchronize with a PC or NTP server Time Setting Synchronize device time to the connected PC NTP Settings Enter the desired NTP server address NTP Interval Control how often the devic...

Page 13: ...ings Select the outlet the device is linked to Script Edit Edit and register scripts Script Setting Outlet Name Script Execution Enable or disable script execution Script Number Choose the script number to execute IPAddress Enter the target device s IP address Port Enter the port number to be used Login ID Enter a user name with administrator privileges Password Enter the password tied to the abov...

Page 14: ... configuration options Register up to 5 users for this category User ID Maximum 8 single byte characters Duplicate registrations are not allowed Password Maximum 16 single byte characters Duplicate registrations are allowed Attention User name and password for TELNET connectivity must be changed separately through command line 13 Security Set Login and IP filter Login setting Set to Enabled or Dis...

Page 15: ...port for TELNET Related items Login Timeout sec Configure how long the unit waits for login credentials Http Refresh Enable to automatically refresh the page at desired intervals Set the direct web command control to Enabled or disabled Apply Save changes to the settings Changes to network settings are only applied after a CPU reset 15 Network setting Advanced setting Set items for SNMP Network Te...

Page 16: ...300 sec default Multi Power Control Simultaneous power supply control Function enabled and group designation Enabled Set the MAC address control of groups 1 8 controlled side Apply Save and apply changes to the setting 16 Send Test Page Conduct WOL Mail and PING transmission reception tests WakeOnLAN Send test Magic packets set to each outlet are transmitted when the Send button is clicked Mail Se...

Page 17: ...ose the appropriate method multiple selections possible APOP Enable or disableAPOP Mail Setting Control Command Enable or disable control command Control User Name Alphanumeric maximum 63 characters Control Password Alphanumeric maximum 63 characters Mail Subject Body First Line 2 8 Select the content of individual lines User Comment Configure user comments up to 43 single byte characters Notifica...

Page 18: ... 0 no limit Apply Save and apply changes to the settings Method of status judgment and action When PING timeouts from the monitored addresses occur as many times as designated in the No Reply box within the number of PINGs sent as defined in send the device is deemed frozen or in abnormal condition The Action is then executed Attention When a tick mark is applied in the Advanced Setting the number...

Page 19: ...imeouts until the action is executed 1 99 times Action Max Count Action Max Count limits the number of times the chosen action is repeated when timeouts continue to occur AboutActions None Heartbeat disabled On The outlet is turned ON upon heartbeat timeouts No further actions are taken even if heartbeat packets are received afterwards On following The outlet is turned ON upon heartbeat timeouts T...

Page 20: ... s system information Items shown Device name Version Model name Outlet 1 4 name Internal time of the device Virtual outlet 1 8 name MAC address IP address Subnet mask Default gateway NTP server address HTTP function HTTP port TELNET function TELNET port LAN access speed 23 Help Provides description of status display of the unit control commands etc Mail or Web command control Description of comma...

Page 21: ... at outlet n Reversed POS Power status at all outlets XPOS Power status detail at all outlets Internal information PASS Change password Command list VER Version information XXXX Value of variable XXXX LIST List of variables XXXX yyyy Changing variable XXXX WRITE Write SAVE Call the variable in the write format TCP Show current TCP status CPURESET CPU reset LOG n Show LOG LOGB Show LOG reverse LOGC...

Page 22: ...e ON OFF function Status Monitoring Transmission of ICMP Notifying function SNMP trap UDP packet Mail notification WOL compatibility Equipped Sending magic packets Shut down function Script communication TELNET Hardware Specification Interface LAN 1 RJ 45 10BASE T 100BASE TX per IEEE802 3 Rating Max controllable power 120 V 12A Power consumption Max 5 8W Input power voltage AC100 120V 50 60Hz Serv...

Page 23: ...tric Co LTD shall not be held liable for any trouble etc due to use of the product for a purpose other than intended or in a way not authorized in this Manual or due to repair or modification to the product by any party other than Meilkyo Electric Co LTD and its authorized representatives 6 Meilkyo Electric Co LTD shall not be held liable for any trouble due to installation of an optional device o...

Page 24: ... during transportation or shipment d Damages resulting from misuse abuse disassembly repair or modification of the product e Damages resulting from fire gas earthquake lightning water wind or any other natural events which may cause unusual electrical load on the product f Any damage caused by devices other than those designed and manufactured by Meikyo Electric Co LTD 4 This warranty is valid onl...

Reviews: