Rev: G1
Y-chute Interface Connector
Connections to the Y-chute are made with a Molex type 6471 19-way. This connector is
fitted to the dual entry (coin and token) system only. It provides an interface for the machine
to inhibit acceptance of any coin/token and also gives a signal to the validator to inhibit coins
during token input and to inhibit tokens during coin input.
This interface is not supplied with the single entry system.
Pin No.
Function
Input / Output
Notes
1
12 Volts
Output
12 volts supply to the validator
2
Inhibit F
Output
Inhibit signals to the validator
3
Inhibit E
Output
4
Inhibit D
Output
5
Inhibit C
Output
6
Polarisation
-
-
7
Inhibit B
Output
Inhibit signals to the validator
8
Not Used
-
-
9
Not Used
-
-
10
0 Volts
Output
0 volts common to the validator
11
0 Volts
Input
0 volts common input to Y-chute
12
Polarisation
-
-
13
Not Used
-
-
14
Inhibit B
Input
Inhibit signal from the machine
15
Inhibit C
Input
16
Inhibit D
Input
17
Inhibit E
Input
18
Inhibit F
Input
19
12 Volts
Input
12 volts input to the Y-chute
Summary of Contents for CASHFLOW 9520
Page 1: ...MEI 2003 Rev G1 CASHFLOW 9520 9524 9528 SELECTOR SYSTEMS DESIGN GUIDE...
Page 33: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 33 Rev G1...
Page 34: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 34 Rev G1...
Page 35: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 35 Rev G1...
Page 36: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 36 Rev G1...
Page 37: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 37 Rev G1...
Page 38: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 38 Rev G1...
Page 39: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 39 Rev G1...
Page 48: ...CashFlow 9520 9524 9528 Design Guide HELPING YOU DELIVER YOUR REPRESENTATIVE...