Frequency setting
0 0 0 0 P02.05
0 0 0 1 P13.01
0 0 1 1 P13.03
0 1 1 1 P13.07
1 1 1 1 P13.15
4.7 Slewing control parameters (Group P13)
Slewing control vortex parameter values: P25.02 choose that whether Y1 is needed to carry out vortex
control; P25.03 is used to control the ratio of the output of the vortex, the value is recommended not to
exceed 100%. P25.04 Stop vortex retention time.
Slewing control operation deadband, the running command must be started again through this time delay
when a running command is finished.
4.8 Lifting control parameters(Group P26)
The running command must be started again through this time delay when a running is finished.
With voltage with speed enabled under lifting control mode. When the grid voltage is below the rated
value of a certain value, in order to protect the drive and the motor, automatically reduce the output
frequency of the drive.
Please refer to [P60.11] ~ [P60.14]
Only valid for closed-loop control.
0: Enable.
1: Disable. You can not switch from forward to reverse directly, and vice versa.
The necessary delay time from brake closing to the next start in closed loop control.
The shortest brake delay of closed loop lifting cross
0.0~10.00s(0.10)
P26.09
Forward reverse cross enabled
0~1(0)
P26.08
Open loop uplink breaking superposition frequency
0.00~5.00Hz(2.00)
P26.07
Open loop downlink breaking superposition frequency
0.00~5.00Hz(3.50)
P26.06
With voltage with speed enabled
0~1(0)
P26.05
Lifting control shutdown dead time
0.00~20.00s(1.50)
P26.00
Slewing control operation deadband
0.0~10.00s(0.00)
P25.09
Stop vortex retention time
0.0~10.00s (6.50s)
P25.04
Vortex control coefficient
0.0~200.0%(80.0%)
P25.03
Y1 vortex control selection
0~1(0)
P25.02