background image

5

flag

Alarm 1 mode

setting

3652

Alarm

2

mode

setting

3656

Alarm

3

mode

setting

3660

Alarm

4

mode

setting

3664

Alarm dead zone

setting

3668

Alarm delay times

3672

Operation amount

selection at alarm

6727

6728

6729

6730 6731

6732

6733

6734

6735

6736

6737

6738 6739

6740

6741

6742

Operation amount

at the time of

alarm

6759

6760

6761

6762 6763

6764

6765

6766

6767

6768

6769

6770 6771

6772

6773

6774

External input

status

3680

3681

Cold junction

temperature

3620

Module parameter

saving

3684

Module software

version

information

3688

Thermostat

identification

code

3692

System error status word

3612

Bit status

ON(1)

OFF(0)

Bit0:Error

When any one of b1 ~ b7 is 1, this
flag is 1.

No error

Bit1:Remain

Bit2:Hardware
malfunction

AD converter or other hardware
failure, all channels AD conversion
stop

The
hardware
is normal

Bit3:Parameter
setting error

When there is an error in the
internal parameters of MTCV, this
flag will become 1.

Data
backup is
normal

Bit4:Cold junction
temperature
compensation error

Cold junction measurement
temperature abnormal

The cold
junction
is normal

Bit5:Remain

Bit6:Remain

Bit7~Bit15:Remain

Broken even error status word

3613

Bit status

ON(1)

OFF(0)

Bit0 ~ Bit15 broken
couple detection

When the thermocouple of channel 1 ~
16 is broken, the flag bit is 1

No
channel
break
fault

7. Common problems and solutions

When the module does not work properly, please check in turn:
(1) the connection of the power line and the condition of the relevant
switches and protection appliances, so as to ensure the reliable power
supply of the module;
(2) whether the wiring of user terminals is firm;
(3) check whether the 24Vdc power supply is overloaded.
(4) check the application to ensure that the correct operation method
and parameter range are selected in the application. Special attention
should be paid to the BFM area with special operation timing.

If you still cannot work after the above check, please refer to the
following table.

Phenomenon

Possible Causes

Countermeasures

POWER and

other LED are

off

Loss of power supply or low

voltage

Check the power status and

eliminate

Power switch off or fuse

blown

Check the condition of the

switch, wire or fuse and

eliminate it

Abnormal power wiring
Power supply is damaged

Check and confirm: whether

the voltage between 24V +

and 24V- terminals is within

the normal range

POWER LED

flashes

intermittently

Unstable power supply
Module damaged

RUN LED is off

or on

Module shutdown or crash

Replace the module

RUN LED

flashes slowly

Possible system error

Please check the 3612, 3613

Broken couple error

The output

cannot be

turned off

(OFF)

External wiring contact

short circuit

Check connection and

troubleshoot

The output transistor is

damaged

Replace the module

The output

status indicator

is inconsistent

with the actual

output status

The output transistor is

aging or damaged, or the

indicator is damaged

The serial port

cannot

communicate

normally

The cable connection is

poor, or the signal

properties of the connection

line are wrong, such as A0

and B0 are reversed

Connect the positive and

negative signal lines correctly

Inconsistent setting of

communication

master-slave

characteristics, such as

baud rate, parity, data bits,

address

Set the communication

parameters to be consistent

The communication protocol of

the master and slave is

inconsistent, set the

communication protocol to be

consistent

1

Warranty scope refers to the programmable controller body.

2

The warranty period is 18 months

, during the warranty period of

normal use, the product failure or damage, our company free

maintenance.

3

T

he warranty period starts from the date of production

. The

machine code is the only basis to judge the warranty period. The

equipment without machine code shall be treated as overinsured.

4. Even within the warranty period, a certain maintenance fee will be

charged if:

(1)Failure to operate according to the user's manual;
(2)Machine damage caused by fire, flood, abnormal voltage, etc.
(3)Damage caused when a programmable controller is used for

unusual functions.

(4)Self-disassembly programmable controller
5. The service fee shall be calculated according to the actual cost. If

there is another contract, the contract shall take precedence.

6.If you have any problem, you can contact the agent or contact us

directly.

SHENZHEN MEGMEET CONTROL TECHNOLOGY CO., LTD

Add

5th Floor, Block B Unisplendour Information Harbor, Langshan Road,

Shenzhen

Tel

400-666-2-163

fax

(+86)0755-86600999

Postcode

518057

Web

www.megmeet-ia.com

Reviews: