24 Chapter
IV
Dex PM3000
Full-Digital Control CO
2
/MAG/MIG Multi-FunctionWelding Machine
1.
Press the "Function" keymore than 3 seconds to enter the internal menusettings and the LED will be
on. Press "Function" key to exit the internal functions settings, the LED will go out.
2.
Enter the internal menu settings, select the parameters, and press the "Execution" key to confirm;
When the LED displays "OFF", it would use the default welding power parameters.
Table4-3Internal Functions
Function
Code
Function Name and Meaning
Adjusting Range
Step
Length
Default Value
F01
Reset to Factory Settings
F10
Slow Wire Feeding Speed
1.4
~
18m/min.
0.1 m/min.
2.4m/min.
F11
Pre-gasTime
0
~
25s
0.1s
0s
F12
Soft-Start Time
0.001
~
0.999s
0.001s
Automatic Matching
F13
Transition Time of Wire Feeding Speed
0.01
~
9.99s
0.01s
0.1s
F14
Post-gas Time
0
~
25s
0.1s
1s
F15
Wire Inching Speed
1.4
~
8 m/min.
0.1 m/min.
Automatic Matching
F20
DC Burn-Back Voltage
12
~
30V
0.1V
12V
F21
DC Burn-Back Time
0.00
~
1.00s
0.01s
Automatic Matching
F22
DC Chopping Time
0.00
~
1.00s
0.01s
0.24s
F23
Quick Rising Slope of DC Welding
Short-Circuit Current
1~300
1
Automatic Matching
F24
Quick rising Amplitude of DC Welding
Short-Circuit Current
0~500A
1A
Automatic Matching
F30
Current Amplitude of Pulse Peak
200
~
420 A
1A
1250 A
F31
Current Time of Pulse Peak
16
~
160
1
35
F34
Pulse Burn Back Time
0
~
1 s
0.01 s
Automatic Matching
F35
Pulse ChoppingTime
0
~
250
1
53
F40
DoublePulse Frequency
0.2
~
10
0.1
1
F41
DoublePulse Duty Cycle
1
~
99
1
50
F42
DoublePulse Intensity
0
~
50
1
20
F43
CorrectedValue of Weak Pulse Voltage
-30
~
30
1
0
F44
CorrectedValue of Intense Pulse Voltage
-30~+30
1
0
F52
MMA ArcStrikingCurrent
0
~
400 A
1A
300A
F53
MMA Hot-StartCurrent
0
~
60 A
1A
50A
F54
MMA ThrustingCurrent
0
~
50 A
1A
30A
F55
DC Welding Energy Control
0~200
1
0
FB0
Software Version Query
FB1
Error Record
0
~
199
FB2
Machine Model Query
FC2
MMA function Switch
OFF
Slow Wire Feeding Speed
(
F10
)
The speed of wire feeding before arc starting.
1.
Enter into internal function, and adjust the panel knob to F10.Press the "Fn" key, and the right nixie
tube flashes.
2.
Turn the knob on the right panel to adjust the F10 parameters (shownin table 4-4), press the "Fn" key
to confirm, and F10 parameter setting is completed.
Table4-4 Parameter Table of Slow Wire Feeding Speed
Function Code
Unit
Adjusting Range
Step Length
Default Value
F10
m/min.
1.4
~
18 m/min.
0.1 m/min.
1.4 m/min.
Step