16 Chapter
III
Dex CM3000
Full-Digital Control CO
2
/MAG/MIG Multi-FunctionWelding Machine
Fig.3-10 Model Query Display Interface
2.
Press the "FN" key,nixie tube displays welder model, as shown in figure 3-11.
Fig.3- 11 Model Display Interface
MMA-Function Switch
(
FC2
)
1.
Enter into internal menu by long pressing “Fn” key; turn the panel knob to FC2.
2.
Rotating the right knob to ON and then MMA function will be turned on.
3.
Press “Function” key again to exit from internal menu.
Swith of Rapid Welding mode / Stardard welding mode (FC0)
1.
Enter into internal menu by long pressing “Function” key; turn left panel knob to FC0.
2.
Rotating the right knob to ON and then Quick Welding Function will be turned on.
3.
Press “Function” key again to exit from internal menu.
Fig.3- 12Display Interface
Restore Factory Settings (F01)
1.
Enter into internal menu by long pressing “Function” key; turn the panel knob to F01.And nixie tube
will be displayed as Fig. 3-13.
Fig.3-5 Restore Factory SettingsDisplay
2.
Long press "Function" key, and theLEDdisplayshows "good" and flashing which means successful
restoring factory settings (shown in fig.3-14).
Fig.3-14
"
Good
"Display Interface
Tips
After restoringfactory settings, except the store/recall parameter and locking passwords, all other parameters will
be restored to factory settings. Please use this function with care!
Step
Step
Step