![Meggitt F145 Series Maintenance Manual Download Page 25](http://html1.mh-extra.com/html/meggitt/f145-series/f145-series_maintenance-manual_1765645025.webp)
Meggitt Fuelling Products
Maintenance Manual (MMF145)
Pressure Fuelling Nozzle
–
F145 Series
USE OR DISCLOSURE OF DATA ON THIS PAGE IS SUBJECT TO THE RESTRICTIONS ON THE TITLE PAGE OF THIS DOCUMENT
05 Jan 2015
Revision 6.4
19
CLEANING
1.
Cleaning Materials
Refer to
Table 8
for recommended cleaning materials. Equivalent items may be used.
Table 8. Recommended Cleaning Materials
DESCRIPTION
SPECIFICATION
SOURCE
Alcohol, Isopropyl
ASTM D770
Commercially available
Bags, Plastic
-
Commercially available
Brush, Bristle, Stiff, Non-metallic
-
Commercially available
Pick, Teflon
-
Commercially available
Solvent, Dry Cleaning
P-D-680, Type 2
Commercially available
Tissues, Lint-free
-
Commercially available
2.
Cleaning Procedures
DRY CLEANING SOLVENT AND ISOPROPYL ALCOHOL ARE
HAZARDOUS MATERIALS. BEFORE USE, READ AND OBEY THE
MATERIAL SAFETY DATA SHEET (MSDS) INSTRUCTIONS FOR
CORRECT HANDLING. FAILURE TO OBEY THIS WARNING MAY
RESULT IN PERSONAL INJURY, LONG TERM HEALTH HAZARDS OR
DEATH.
A. Clean all of the metal parts by washing them thoroughly in dry cleaning solvent. Remove any
stubborn deposits by scrubbing them with a non-metallic stiff bristle brush. Use a Teflon® pick to
remove any blocked ports, grooves, and flow passages.
B. Make sure the flow passage of the nozzle body (
IPL Figure 1,
1 or 1A) is clean, especially where
the plugs (10) are installed.
C. Clean all of the non-metallic parts by wiping them with clean lint-free tissues slightly moistened with
isopropyl alcohol.
Note:
All parts must be free of corrosion, dirt, grease, oil or any other foreign matter.