6. Functions

Area Measurement

Pressing the 

 button once will start the area measurement function.

Press the 

 button to take the first length measurement (e.g. length).

Press the 

 again to take the second length measurement (e.g. width).

The result of the area measurement is displayed in the third summary line of the display. The two individually measured 
values are displayed in lines 1 and 2.

Volume Measurement

By pushing the Unit button twice, it will start the volume measurement function.

Press the 

 button to take the first length measurement (e.g. length).

Press the 

 again to take the second length measurement (e.g. width).

The result of the area measurement from the values already measured is displayed in the summary line.

Pressing 

 takes the third distance measurement (e.g. height). The value is displayed in the second line.

The resulting volume measurement is displayed in the third summary line. The last two measured values are displayed in 
lines 1 and 2.

Historical Storage 

The previous 20 measurements or calculated results can be recalled on the display, in reverse order (newest first). To 
enter memory mode, quick press this button to cycle through the stored results. The memory location is shown at the 
top of the display.
You can clear all stored records by pressing MEM and CLR buttons simultaneously when in historical storage mode.

6. Technical Specifications

Range   

 

 

 

0.05 to 50 m (0.2 to 164 ft) *  

Measuring accuracy up to10m   

Typically: ±1.5 mm (±1/16 in)** 

Standard 

deviation 

  2 

σ

Measuring units  

 

 

m, in, ft

Laser Class 

 

 

 

Class II  

Laser Type 

 

 

 

650 nm, <1mW  

Smallest unit displayed   

 

1mm  

Area, Volume Calculations 

 

Built-in spirit level 

 

 

Continuous Measurement 

 

Min/Max Distance Tracking 

 

Backlit 

display 

   √

www.megger.com

5

MLM50 Laser Distance Meter

Summary of Contents for MLDM50

Page 1: ...MLM50 Laser Distance Meter USER MANUAL...

Page 2: ...f area and volume 2 Safety Warnings Safety Warnings and Precautions must be read and understood before the instrument is used They must be observed during use THE INSTRUMENT MUST BE USED ONLY BY SUITA...

Page 3: ...for 1 second to initiate automatic measurement mode Clear Button The last action is cancelled or the data display is cleared If in History storage mode by pressing the Storage and Clear button simult...

Page 4: ...0 000 ft 4 0 000 ft 0 000 ft 0 000 ft 5 0 00 1 16 0 000 ft 0 000 ft 5 Measuring Single Distance Measurement Press to activate the laser Press again to trigger the distance measurement The measured va...

Page 5: ...nt e g height The value is displayed in the second line The resulting volume measurement is displayed in the third summary line The last two measured values are displayed in lines 1 and 2 Historical S...

Page 6: ...he deviation in distances above 10 m 33 ft can increase by 0 15 mm m 0 0018 in ft Product manufactured in China 7 Inserting or Replacing Batteries i Remove the rear battery compartment lid ii Insert 2...

Page 7: ...ers of Megger products in other regions should contact their local Megger office or distributor Warranty 3 years This product is warranted to the original purchaser against defects in material and wor...

Page 8: ...rves the right to change the specification or design without prior notice Megger is a registered trademark The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and is...

Reviews: