3.4 Standard accessories
The following accessories are included as standard
when ordering an IDAX with 18 meter cables:
▪
Mains cable
▪
Earth/ground cable, 2.5 mm
2
, 5 m (15 ft)
▪
Generator cable, 18 m (60 ft)
▪
Measuring Cable, Red, 18 m (60 ft)
▪
Measuring Cable, Blue, 18 m (60 ft)
▪
Soft bag for cables and accessories
▪
uSB memory stick
▪
IDAX for Windows
▪
user Manual, IDAX
▪
Test & Calibration Certificate
▪
uSB cable, A - B, 2 m (5 ft) (IDAX 300/322 only)
▪
Transport case IDAX 300 (IDAX 300 only)
Standard accessories for IDAX 322
▪
Measuring cable, 21 m (70 ft),
▪
Measuring cable, 21 m (70 ft),
▪
HV generator cable 20 m (65 ft)
▪
Interlock switch
3.5 Installation
The IDAX 350 comes with the IDAX software
already installed on the internal computer. On the
IDAX 300/322 and if you want to use the IDAX 350
with an external PC you have to install the software.
Important
On the IDAX 350 make sure to close the
IDAX software and the operating system
before turning off the unit using the on/
off mains switch and disconnecting the
mains cord.
IDAX 350 can be used as a central computer
controlling other test instruments e.g Megger FRAX
and TTR. Megger
software
is checked for co-existence
and can be used together with IDAX 4 and 5. Be
careful if installing other manufacturer’s software
on the IDAX unit. Doing so may prevent the IDAX
software from working as intended.
Installation of IDAX 5 software
Make sure your software is properly installed. IDAX
software will install on Windows XP, Vista, 7 and 10.
▪
To be able to install this software package, you
MuST be logged in with Administrator’s rights.
▪
IDAX 5 software also requires “Microsoft .NET
Framework 4.0” to be installed, if the installation
program found that .NET Framework is not installed
in your computer, then installation software will
automatically start this installation. This may take a
while (several minutes).
▪
IDAX 5 software will also install the necessary
drivers to communicate with the IDAX 300/322
instrument using the uSB port. The uSB cable must
not be connected to IDAX 300/322 at this time. In
case of IDAX 350, switch the uSB port PC selector
to “EXT” (external computer position).
Summary of Contents for IDAX 300
Page 2: ......
Page 5: ...AG033586EE ZP AG03E IDAX 300 322 350 5...
Page 11: ...AG033586EE ZP AG03E IDAX 300 322 350 11 2 Safety...
Page 19: ...AG033586EE ZP AG03E IDAX 300 322 350 19 3 Instrument description...
Page 33: ...AG033586EE ZP AG03E IDAX 300 322 350 33 4 IDAX 5 Software...
Page 35: ...AG033586EE ZP AG03E IDAX 300 322 350 35 5 Calibration...
Page 43: ...AG033586EE ZP AG03E IDAX 300 322 350 43...
Page 45: ...AG033586EE ZP AG03E IDAX 300 322 350 45 8 Specifications...