background image

15

Accessories

Standard Accessories supplied with all instruments 

Test lead pouch (lid mounted)   

 

 

1005-623

User 

guide 

on 

CD 

    2000-869

Warranty 

book. 

    6170-618

Test leads supplied with instruments

1006-603 DLRO10HD  

= DH4-C probe 1,5m leads  

1006-444

1006-604 DLRO10HD  

= KC1 kelvin clip 3m leads  

1006-462

1006-657 DLRO10HD  

= No test leads supplied

Optional Accessories at extra cost 

Calibration Shunt, 10 Ω, current rating 1 mA. 

 

249000 

Calibration Shunt, 1 Ω, current rating 10 mA. 

 

249001 

Calibration Shunt, 100 mΩ, current rating 1A. 

 

249002 

Calibration Shunt, 10 mΩ, current rating 10 A. 

 

249003 

Certificate of Calibration for Shunts, NIST  

 

CERT-NIST 

Replacement tips for DH4 and DH5 handspikes. 

 

 Needle 

point 

   25940-012 

 Waffle 

end    25940-014

The CATIII 300 V rating on the DLRO10HD is only valid when the instrument 

is used with the optional terminal cover to provide the required 
creepage and clearances at the instrument terminals. Although 
the terminal cover may be used with any test leads, only 

Megger DH4 and DH5 duplex handspikes have 
suitable probe insulation to comply with the 
requirements of IEC61010-1 and the CATIII 300 
V rating.

Normal test leads not fitted with in-line connector 
Duplex Leads 

DH5 straight duplex handspikes (2). 

One has indicator lights.  

2.5m/8ft 

6111-517

Terminal cover (use in conjunction with DH4 test leads supplied as standard, 
or optional DH5 test leads for CATIII 300 compliance)  

1002-390

Duplex Handspikes (2)with spring loaded helical contacts. 
 

2m/7ft 242011-7

DH1 only 1 lead supplied 

2.5m/8ft 

6111-022 

DH1 only 1 lead supplied 

5.5m/18ft 

242011-18

DH2 

6m/20ft 6111-023 

 

9m/30ft 242011-30

DH3 

9m/30ft 6111-024

Straight Duplex Handspikes (2)  
Heavy Duty with fixed contacts. 

2m/7ft 

242002- 

 

5.5m/18ft 242002-18 

 

9m/30 ft 

242002-30

Duplex Heavy Duty 5cm (2”)  
C-Clamps. (2)   

2m/7ft 

242004-7 

 

5.5m/18ft 242004-18 

 

9m/30ft 242004-30

Duplex handspikes with replaceable Needle Points  
 

2m/7ft 242003-7

Duplex 1.27 cm (1⁄2”) Kelvin Clips. (2)  
 

gold plated 2m/7ft 

241005-7 

Summary of Contents for 1006-603

Page 1: ...M DLRO10HD 10 A Digital Low Resistance Ohmmeter USER GUIDE...

Page 2: ...the LCD will flash at end of a test on an inductive load whilst a discharge current is still flowing and will stop flashing when the current has decayed to less than 1 mA For testing large inductive r...

Page 3: ...onnectors to confirm that their condition is good with no damaged or broken insulation Charging and mains line operation In normal circumstances the instrument is completely safe However in case of an...

Page 4: ...the instrument and wipe it with a clean cloth slightly damped with soapy water or Isopropyl alcohol IPA Symbols used on the instrument G Caution Refer to accompanying notes F HV warning t Equipment pr...

Page 5: ...10 Amp tests to be completed on a single charge An auto power off function preserves battery life when operating from battery power The battery contains intelligent circuitry which prevents damage to...

Page 6: ...achieved Electromagnetic noise induced into the leads can interfere with a reading A noise symbol alerts the user and prevents a measurement when the instrument detects noise above its threshold When...

Page 7: ...connect the test leads and press the test button The measurement is updated every three seconds until the circuit is broken Please note that in this mode both the current and voltage leads must be co...

Page 8: ...rnal voltage is applied between the terminals and the instrument is on the HV warning Fwill flash on the display This is a warning that the item under test is live and might be dangerous and testing i...

Page 9: ...ontacts connect L1 will extinguish 4 No lamps will show during the test unless contact fails 5 Lamp L2 will light a continuous green when current flow has decayed to less that 1 mA to signal end of te...

Page 10: ...the contrast adjust button Contrast setting will scroll through its range from min to max and back to min etc The backlight ON OFF button toggles the state of backlight that will timeout if left on f...

Page 11: ...th arrows to indicate direction of current flow The large arrow at the top of the display between C1 and C2 indicates measurement current flow LCD Icons Battery icons with battery charge level indicat...

Page 12: ...fitted with a 3 Amp fuse The instrument can be powered from 90 265 Vrms a c at 50 60 Hz The battery will charge as long as the mains supply is connected except when a test is in progress For optimum b...

Page 13: ...nal mode will introduce an undefined error if an external EMF is present Basic accuracy at reference conditions Test Current Resistance Range Resolution as displayed Basic Accuracy Full scale voltage...

Page 14: ...ode selected IP rating IP65 case closed IP54 battery operation Safety rating In accordance with IEC61010 1 CATIII 300 V when used with optional terminal cover details in ordering information Applicati...

Page 15: ...s at the instrument terminals Although the terminal cover may be used with any test leads only Megger DH4 and DH5 duplex handspikes have suitable probe insulation to comply with the requirements of IE...

Page 16: ...the printed circuit board If the protection of an instrument has been impaired it should not be used and be sent for repair by suitably trained and qualified personnel The protection is likely to be...

Page 17: ...oducts is a reminder not to dispose of the product at the end of it s product life with general waste Megger is registered in the UK as a Producer of Electrical and Electronic Equipment The Registrati...

Page 18: ...pliance with Directive 2014 53 EU Other equipment manufactured by Megger Instruments Limited described in this user guide is in compliance with Directives 2014 30 EU and 2014 35 EU where they apply Th...

Page 19: ...enaff 78190 TRAPPES France T 33 0 1 30 16 08 90 F 33 0 1 34 61 23 77 E infos megger com Other technical sales offices Toronto Canada Sydney Australia Mumbai India Madrid Spain and the Kingdom of Bahra...

Reviews: