![background image](http://html1.mh-extra.com/html/megasat/hd-1-kompakt/hd-1-kompakt_user-manual_1765123042.webp)
4. Instructions for measuring with a mobile device
12
ENGLISH
4.4 Spectrum
This submenu displays the spectrum of the
current live signal on the mobile device.
You can set the LNB supply manually. The
values are Off, 13V and 18V.
You can also set the beginning and the end
of the frequency for the spectrum range.
Press and hold and drag the slider until the
desired frequency is limited.
Swipe left or right to change the LNB values.
You can set the 22k status manually. The va-
lues are Off and On.
Note:
The LNB value „Universal 10600“ is
for measuring the high band, „Uni-
versal 9750“ for the low band. The
values of the LNB power and the
22K circuit are adjusted automati-
cally when changing.