background image

Axis Mini Grid 44 Ch Mode

 

 

 

DMX Channel

 

Function

 

Description

 

Value

 

Init Value

 

1

 

Pan

 

Pan Course

 

0

-

255

 

128

 

2

 

Pan Fine

 

Pan Fine

 

0

-

255

 

128

 

3

 

Tilt

 

Tilt Course

 

0

-

255

 

128

 

4

 

Tilt Fine

 

Tilt Fine

 

0

-

255

 

128

 

5

 

Pan & Tilt Speed

 

Pan & Tilt Speed (fast to slow)

 

0

-

255

 

0

 

  

  

No Function

 

0

-

15

 

  

6

 

Infinity Pan

 

Forward (fast to slow)

 

16

-

135

 

0

 

  

  

Backwards (slow to fast)

 

136

-

255

 

  

  

  

No Function

 

0

-

15

 

  

7

 

Infinity Tilt

 

Forward (fast to slow)

 

16

-

135

 

0

 

  

  

Backwards (slow to fast)

 

136

-

255

 

  

  

  

No Function

 

0

-

9

 

  

8

 

Control

 

Reset

 

10

-

20

 

0

 

  

  

No Function

 

21

-

255

 

  

9

 

LED Intensity

 

Pixel 1 Red

 

0

-

255

 

0

 

10

 

LED Intensity

 

Pixel 1 Green

 

0

-

255

 

0

 

11

 

LED Intensity

 

Pixel 1 Blue

 

0

-

255

 

0

 

12

 

LED Intensity

 

Pixel 1 White

 

0

-

255

 

0

 

"

 

"

 

"     "

 

"

 

  

41

 

LED Intensity

 

Pixel 9 Red

 

0

-

255

 

0

 

42

 

LED Intensity

 

Pixel 9 Green

 

0

-

255

 

0

 

43

 

LED Intensity

 

Pixel 9 Blue

 

0

-

255

 

0

 

44

 

LED Intensity

 

Pixel 9 White

 

0

-

255

 

0

 

Rigging The Fixture

 

Caution!

 

 

1.

 

The installations must be carried out by an authorized dealer or trained professional.

 

2.

 

Unit may cause severe injures if you have doubts concerning the safety do not install.

 

3.

 

Unit is to be 24inches away from flammable materials (decoration material)

 

4.

 

Use high quality installation equipment to hang unit.

 

When rigging a unit it is very important that you follow common safety procedures.  Rigging requires extensive experi-

ence including but not limited to calculating working loads, material being used and periodic safety inspections.  If you 

lack these qualifications, do not attempt the installation yourself, instead use a professional structural rigger.

 

 

When rigging the unit always be secured with a secondary safety attachment.  The installation location of the projector 

has got to be built in the way that it can hold 10 times the weight for 1 hour with out any harming.  Installation should be  

checked at least one time a year by a skilled person.

 

Caution!

 

 

1.

 

The installations must be carried out by an authorized dealer or trained professional.

 

2.

 

Unit may cause severe injures if you have doubts concerning the safety do not install.

 

3.

 

Unit is to be 24inches away from flammable materials (decoration material)

 

4.

 

Use high quality installation equipment to hang unit.

 

When rigging a unit it is very important that you follow common safety procedures.  Rigging requires extensive experi-

ence including but not limited to calculating working loads, material being used and periodic safety inspections.  If you 

lack these qualifications, do not attempt the installation yourself, instead use a professional structural rigger.

 

 

When rigging the unit always be secured with a secondary safety attachment.  The installation location of the projector 

has got to be built in the way that it can hold 10 times the weight for 1 hour with out any harming.  Installation should be  

checked at least one time a year by a skilled person.

 

11

 

Summary of Contents for AXIS MINI GRID Q9

Page 1: ...MANUAL Table of Contents Safety Information 3 Specifications 4 Main Power Connection 5 DMX 512 Connection 5 Main Control Menu 6 DMX Profile 9 Rigging the Fixture 11 Cleaning Maintenance 12 Parts List...

Page 2: ......

Page 3: ...ity clamps or bolts when positioning unit 3 Do not open unit while it is on risk of electrical shock Check that the unit has not been damaged during transport Protection Against Fire 1 Maintain a mini...

Page 4: ...er Connectors Power Con type in and out Thermal Maximum ambient temperature 100 F Maximum surface temperature 130 F Fastening System Single Quick Release Clamp Mounts Lens Angle 8 Electrical Specifica...

Page 5: ...nection The fixture is equipped with 3 and 5 pin XLR Sockets for DMX input and output The sockets are wired in parallel Only use a shielded twisted pair cable designed for RS 485 and 3 or 5 pin XLR pl...

Page 6: ...Red Intensity 10 Green Intensity 11 Blue Intensity 12 White Intensity 13 Shutter Strobe 14 Color Macro 15 Color Activated Macro 16 Control 16Ch 54 C 44 Ch 1 Pan 2 Pan Fine 3 Tilt 4 Tilt Fine 5 Pan Til...

Page 7: ...vert 5 Slave Mode 6 Audio Mode 7 Pan Invert 8 Tilt Invert Press the knob to select Tilt Invert option Select yes or no Tilt Invert 5 Slave Mode 6 Audio Mode 7 Pan Invert 8 Tilt invert 9 Display Rotate...

Page 8: ...ob and select yes to have the fixture run throw a built in program testing all functions Auto Test 13 Reset 14 Auto Test 15 P T Degree Exit Press the knob to select Pan and Tilt extreme positions from...

Page 9: ...LED Intensity Green Dimmer 0 255 255 8 LED Intensity Blue Dimmer 0 255 255 9 LED Intensity White Dimmer 0 255 255 No Function 0 6 10 Shutter Random Strobe slow to fast 7 128 0 Strobe slow to fast 129...

Page 10: ...9 255 No Function 0 1 Macro 1 slow to fast 2 19 Macro 2 slow to fast 20 39 Macro 3 slow to fast 40 59 Macro 4 slow to fast 60 79 Macro 5 slow to fast 80 99 14 Color Macro Macro 6 slow to fast 100 119...

Page 11: ...t not limited to calculating working loads material being used and periodic safety inspections If you lack these qualifications do not attempt the installation yourself instead use a professional stru...

Page 12: ...ng on usage and environment Environment with foggers will require more periodic cleaning as fog fluid tends to build up residues reducing the light output 2 The cooling fans should be cleaned monthly...

Page 13: ...es no warranties express or implied with respect to any product and Mega Systems specifically disclaims any warranty of merchantability or fitness for a particular purpose Mega Systems shall not be li...

Reviews: