1
Installation Precaution
Requirement of air conditioner
1.
Requirements for electric connection
Safety precaution
2.
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6.
7.
1. Air inlet should be far away from obstacles and do
Selection of installation location
Basic requirement
Installing the unit in the following places may cause
malfunction. If it is unavoidable, please consult the
local dealer:
3.
emitted by the outdoor unit will not affect neighb-
orhood.
will affect the radiation of heat discharge pipe.
2. Select a location where the noise and outflow air
4.
not put any objects near air outlet. Otherwise, it
Please try your best to keep far away from fluor-
1.
The place with strong heat sources, vapors, fla-
2. According to the local safety regulations, use qu-
installing the unit.
alified power supply circuit.
3.
mmable or explosive gas,or volatile objects spread
in the air.
The place with high-frequency devices (such as
welding machine, medical equipment).
4.
escent lamp.
The appliance shall not be installed in the laundry.
5. Be sure to cut off the power supply before proce-
eding any work related to electricity and safety.
6. Do not put through the power before finishing in-
stallation.
7.
8.
For appliances with type Y attachment, the instr-
Must follow the electric safety regulations when
Other places with special circumstances.
It’s not allowed to be installed on the unstable or
motive base structure (such as truck) or in the
corrosive environment (such as chemical factory).
9. The grounding resistance should comply with na-
tional electric safety regulations.
10.
sheet:
11.
with national wiring regulations.
To be in compliance with IEC 61000-3-11, impe-
dance value of power-supply system connected
0.13
ML-PC10AO-K5NNA1A
ML-PH12AO-K5NNA1A
ML-PC12AO-K5NNA1A
models
max |Zsys| unit:ohm
to product must be less than or e qual to the all-
owable maximum value of |Zsys| in the following
■
■
■
uctions shall contain the substance of the following.
If the supply cord is damaged,it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
Properly connect the live wire, neutral wire and
grounding wire of power socket.
The appliance shall be installed in accordance
The air conditioner is first class electric appliance.
It must be properly grounding with specialized gr-
ounding device by a professional. Please make
sure it is always grounded effectively, otherwise
it may cause electric shock.
The yellow-green wire or green wire in air conditi-
oner is grounding wire, which can't be used for
other purposes.
WARNING
Observe all governing codes and ordinances.
Do not use damaged or non-standard power cord.
Be caution during installation and maintenance. Pr-
ohibit incorrect operation to prevent electric shock,
casualty and other accidents.