MegaLife ML-PC10AO-K5NNA1A Owner'S Manual Download Page 13

Check items

 9

Malfunction analysis

Phenomenon

Air conditio-

Move the remote co-

ntroller close to air 

conditioner.

 Turn off the fluoresc-

ence lamp and try it 

again.

 

ner can't 

operate

Power failure?
Is plug loose?

Reinsert the plug.

Solution

Wait after power recovery.

Please check below items before asking for main-

tenance. If the malfunction still can’t be eliminated,

please contact local dealer or qualified professionals.

Whether the air 

switch is tripped 

off or fuse is burnt?

Ask professional pe-

rson to replace air 

switch or fuse.

Is there malfunction 

for the circuit?

Ask professional per-

son to replace circuit.

Poor cooling

(heating)

Is the power too low?

Whether the unit is 

restarted up after st-

opping immediately?

Wait for 3min, and 

then turn on the unit 

again.
Wait after voltage is 

resumed.

Clean the air filter.

Whether the air filter 

is too dirty?

window.

Whether the set tem-

perature is proper?

Adjust the tempera-

ture.

Close door and 

Air conditioner 

Whether door and 

window are closed?

can't receive

signal from 

remote con-

troller or rem-

ote controller

is not sensible.

Whether the unit is 

interfered seriously 

(such as static pre-

ssure, unstable 

voltage)?

Please pull out the 

plug. Insert the plug 

after about 3min, and

then turn on the unit.

Whether remote co-

ntroller is within the 

receiving range?

Whether it's blocked

by obstacles?

Remove the obstacles.

The receiving range 

of remote controller 

is 8m. Do not exced 

this range.

Is sensitivity of rem-

ote controller low?

You can 

heard the 

 "PAPA"

Check the batteries 

of remote controller.

If the power is low,

please replace the 

batteries.

sound of

Whether there's flu-

orescence lamp in

the room?

Whether the unit is

turned on or turned 

off just now?

Heat expansion or 

shrinkage for the 

panel due to change 

of temperature, which

cause friction sound.

There's off 

flavour

off-flavour source.

Eliminate the 

Clean the filter.

There's abn-

ormal sound 

during oper-

ation

there's off-flavour 

source in the room, 

such as furniture, 

cigarette etc.

Disconnect power, 

put through the power 

again, and  then turn

on the unit again.

Whether the unit is

interfered by thunder, 

  radio, etc?

1.Pour out the water inside chassis.

2.If "H8" still exits, please contact profess-

   ional person to maintain the unit.

If the malfunction still occur, please co-

3.

   ntact our after-sales service center.

1.Check if the unit is under high-temperature 

2.Check if the evaporator and condenser

 

■ 

 ●

Water leakage.

Power cord is overheating or damaged.

Abnormal sound during operation.

Off-flavor.

■ 

Do not repair or refit the air conditioner by yourself.

WARNING

■ 

If there’re following phenomenon,please turn off the 

air conditioner and disconnect the power immediat-

ely,and then contact dealer immediately.

are blocked by some objects; if yes, take 

away the objects, power off the unit and

then energize it for operation.

  and high-humidity environment; if ambient 

  temperature is too high, power off the unit 

  and then energize it for operation after the 

  ambient temperature drops to 35

below.

Malfunction code

H8

E8

H3

If operate the air conditioner under abnormal conditi-

on,it may cause malfunction,electric shock or fire hazard.

Troubleshooting

Please contact qualified professionals for

service.

Error code

F1

F2 F4 F0

Phenomenon

Set tempe r-

No air blowed 

out from air 

conditioner

Check items

Whether air outlet or 

air inlet is blocked?

Solution

Eliminate the obstacles.

Under heating mode, 

whether indoor temp-

erature increase set 

temperature? (Cool

& Heat Unit only)

The unit will stop blo-

wing fan after reaching 

set temperature.

ature can't 

be adjusted.

In order to prevent cold 

air, air conditioner will

delay for a while to be

started up, which is the 

normal phenomenon.

It's the normal pheno-

menon. Air conditioner 

is defrosting. After de-

frosting is finished, it 

will resume operation.

Whether evaporator 

is defrosted? (obser-

ve it by pulling out 

the filter)

Temperature can't be 

adjusted under auto 

mode.

Whether the unit op-

erates under auto 

mode?

Temperature setting 

range: 16°C-30°C .

Whether the requir-

ed temperature 

exceeds the temp-

erature setting range?

sound

You can heard 

water-flowing 

There's flowing sound 

of refrigerant inside 

the air conditioner, 

which is the normal

phenomenon.

Whether the unit is 

turned on or turned 

off just now?

Whether heating mo-

de is started up just 

now? (Cool & Heat 

Unit only)

Summary of Contents for ML-PC10AO-K5NNA1A

Page 1: ...nstructions Portable air conditioner Model ML PC10AO K5NNA1A ML PH12AO K5NNA1A ML PC12AO K5NNA1A Thank you for choosing our product Please read this Owner s Manual carefully before operation and retai...

Page 2: ...ction for Icons on Display Screen 1 Installation in sash window Optional 1 2 6 8 10 11 12 Function Introduction for Combination Buttons Replacement of Batteries in Remote Controller Maintenance 7 7 12...

Page 3: ...bol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information used to indicate r...

Page 4: ...example open flames an operating gas app liance or an operating electric heater The appliance shall be stored in a well ventilated area where the room size corresponds to the room area as specified f...

Page 5: ...hen contact local dealer When nobody is taking care of the unit please turn it off and remove the power plug or disconnect power Prohibit operating the unit in the bathroom or laundry room Far away fr...

Page 6: ...essionals to deal with it Do not use an extension cord Please put the air conditioner at smooth and flat ground for operation to avoid noise and vibration This air conditioner is equipped with castors...

Page 7: ...OPER 7 Sleep Timer 8 Health WiFi 10 9 Remote controller Some installation accessories can t be discarded On Off Fan Mode Swing 1 Controller panel Guide louver NOTICE 4 5 6 Filter Air inlet Middle drai...

Page 8: ...ir conditioner will give out a sound Meanwhile corresponding indicator on control panel will be bright Under OFF status dual 8 nixie tube on control panel won t display Under ON status dual 8 nixie tu...

Page 9: ...sion of the signal Do not leave the remote control in direct sunlight or ne ar a heater Protect the remote control from moisture and shock Set time TIMER ON TIMER OFF Light Up down swing Child lock Se...

Page 10: ...imer button Health button This function is not applicable for this model Under ON status press this button to set timer OFF Under OFF status press this button to set timer ON Press this button once an...

Page 11: ...ons Temperature display switchover function Under OFF status press and Mode buttons simultaneously to switch temperature display betw een C and F using the remote controller Replace new batteries of t...

Page 12: ...on the air conditioner Eliminate accumulated water in chassis refer to the section of Drainage way for details Check whether window bracket is damaged or not If yes please contact dealer dition Check...

Page 13: ...he unit again Whether the unit is interfered by thunder radio etc 1 Pour out the water inside chassis 2 If H8 still exits please contact profess ional person to maintain the unit If the malfunction st...

Page 14: ...c safety regulations when Other places with special circumstances It s not allowed to be installed on the unstable or motive base structure such as truck or in the corrosive environment such as chemic...

Page 15: ...ews FAN Fan Swing Mode OPER Sleep On Off Timer Health WiFi Optional 1 Mothproof net Bracket Screw Mounting plate Fixed clip Fixed base Sponge B Sponge A Optional 3 Optional 2 Optional 4 Drainage hose...

Page 16: ...age port to drain water After draining insert the rubber plug Press ON OFF button to restart To reach the maximum performance it is not recommended to drain water during Cool mode It is recommended to...

Page 17: ...option from the middle hole place portable on a level surface and make sure garden hose is clear of any obstructions and is directed downward Placing portable on an uneven surface or improper hose in...

Page 18: ...0 465 25 25 25 25 25 25 25 465 127 255 128 128 123 123 Window panel Adjustment panel Extension panel Exhaust cover Fixed base Fixed base Fixed base Fixed base Window panel Adjustment panel Fixed clip...

Page 19: ...ion of window and screw down by a Mounting plate C 1 2 3 4 5 6 7 Assemble the window kit as below 5 For windows with inner width or height of 770mm push two fixed bases to the end of Window Panel A Fo...

Page 20: ...Window panel Stuff the Foam seal A between the glass and the window to prevent air and insects from getting into the room 2 Attach the window panel to the window stool Make sure that the exhaust cove...

Page 21: ...haust cover is attached to the window panel 770mm 1210mm 770mm 1650mm 1210mm 5 Attach the bracket with a screw Recommend ed Bracket Sliding sash window Optional 1 1 Please lay a tabular material under...

Page 22: ...below figure by the manufacturer Note of Installing heat discharge pipe User can adjust the installation method of the discharge pipe basing on the requirement while the similar installation methods...

Page 23: ...4 3 Install the other side of heat discharge pipe clock wise into joint D Joint D Insert joint A of heat discharge pipe into the gro ove until you hear a sound Groove joint A Insert joint A of heat di...

Page 24: ...nd remove the Rear clip by pushing down two PUSH markings slide and close the exhaust cover in the window panel Optional Joint Joint H 1 2 Remove joint F remove joint F from joint H Disassembly for in...

Page 25: ...RD C1 SA M2 YEGN M1 YEGN PE PE RD CAP CAP BN ROOM TEMP BN RD SENSOR RT1 TUBE TEMP SENSOR OUTTUBE TEMP SENSOR RT3 VALVE 4 WAY 4YV WATER MOTOR YEGN RECEIVER BOARD POWER L N BN BK BU WH YEGN GN N2 WATER...

Page 26: ...22 b a Specialist s Manual 4 2 Aptitude requirement for maintenance man repairs should be done only be specialists Safety preparation work 2...

Page 27: ...be avoided as the chlorine may react with the refrigerant and corrode the copper pipe work If a leak is suspected all naked flames shall be rem oved extinguished If a leakage of refrigerant is found w...

Page 28: ...and that ventilation is available Specialist s Manual Decommissioning a Become familiar with the equipment and its ope ration Isolate system electrically Before attempting the procedure ensure that b...

Page 29: ...ng the equipment that is at hand and shall be suitable for the recovery of all the relevant waste transfer note arranged Do not mix refrigerants in recovery units and especially not in cylinders If co...

Page 30: ...66129937317...

Reviews: