stage three, 

activating the batteries

  

Caution:

 

Please ensure the batteries are correctly installed, observe the correct polarity as the PCB may be 

damaged if this is not carried out.

Remove the paper insulator from the lithium 3Vcc battery.

Confi guring your Megalarm wireless system 

First mark one of your P300W units as your master unit (label or write ‘Master’ on the back)

To Cancel the connection with a smoke detector or a stand alone alarm during the set up process

While in step 2 anywhere between points 3 and 8 and you encounter a problem or are not sure that you pressed 
the right button, press the confi guration button for 10 seconds until you hear 4 long beeps which confi rms that any 
connections have been cancelled.

1. Open the master unit and the fi rst slave unit.
    (Slave unit is either another P300W, C300W or D300W)
2. Place the slave next to the master unit.
3. Press the CONFIG button in the slave unit for 5 seconds, 
    the unit will beep to indicate each second, and then release.
    This does not apply to the D300W - see Step 3.
4. Once the unit has sent the confi guration signal the buzzer will pulse 
  and the amber LED will illuminate. 
  The slave now sends a request to be combined with the master. 
  This is indicated by 1 beep every 3 seconds
5. Press the VALID button in the master until you hear a long beep and 
  then release.
6.

 

The slave is now linked to the master unit and will now enter the ‘signal 

  strength’ mode.
7. Take the slave to the preferred location and ensure the signal strength is 
  adequate, the unit will beep indicating the signal strength. You should try to 
  achieve at least a signal strength of 3

     Number of Beeps 

       1   

            2 

                 3 

                   4                         5

     Signal Strength 

Very weak 

         Weak 

            Medium                  Good                  Very good

0330 999 2233

www.fi redepot.co.uk

sales@fi redepot.co.uk

4

Summary of Contents for P300W

Page 1: ...setting up your wireless system P300W C300W D300W and wireless interface Standards NFS 61 936 NFS 32001 EN 54 11 0330 999 2233 www firedepot co uk sales firedepot co uk...

Page 2: ...operation autonomy 5 years with at least 5 minutes alarm Installation Method Surface mounted Sounder Integral 90db within 2 meters Strobe Lights Integral high power LEDs Dimensions 126 W x242 H x75 D...

Page 3: ...em requires that you make a P300W unit the master and all other components slaves Further P300W units and or both C300W or D300W stage one opening and closing your master P300W unit Open your P300W un...

Page 4: ...MCP Refer to Step 2 stage one on how to access the MCP step 2 Your C300W unit stage one opening your C300W unit Simply unscrew the holding screw in the front of the box then lift off the front face s...

Page 5: ...Slave unit is either another P300W C300W or D300W 2 Place the slave next to the master unit 3 Press the CONFIG button in the slave unit for 5 seconds the unit will beep to indicate each second and the...

Page 6: ...he location space provided see below on the right 3 Within 20 seconds of removing the tag press the clear button on the side of the D300Wsmoke detector and the unit will beep release the button and th...

Page 7: ...Battery The manual call point battery is faulty 2 MCP Communication No signal has been recieved from the Battery Fault Replace the defective Lithium 3Vcc CR 17 345 for the MCP including the One instal...

Reviews: