background image

MEGACOUNT is committed to managing environmental impact, and it is our policy to assure the 
environmental integrity of our processes and facilities at all times and to provide environmentally 
safe products

Correct disposal of the device
(Waste Electrical and Electronic Equipment)

(Applies to all Eurasian Economic Union, European Union countries and other Europe countries that 
have accepted the recycling system)

This marking implies prohibition of disposing of the equipment together with other household waste. Device 
contains batteries.
If disposed of incorrectly, batteries can harm a person’s health and the environment. To protect 
environmental resources and support recycling of materials, it is recommended to store batteries separately 
from other waste and dispose of them through a local battery return system. Change of batteries in the 
device by the user is allowed. Information on battery change can be received from the service company. 

22

Summary of Contents for OMEGA-ETH

Page 1: ...megacount io PEOPLE COUNTER User Manual OMEGA ETH...

Page 2: ...MEGACOUNT Ltd Disclaimer MEGACOUNT Ltd ensures that the contents of this document are accurate and complete but is not legally responsible for the information provided The user is fully responsible fo...

Page 3: ...ING BATTERIES WRONG POLARITY CAN LEAD TO COUNTERS BREAKING AND BATTERIES OVERHEATING TO AVOID DAMAGE THAT CAN CAUSE A FIRE OR ELECTROCUTION KEEP THE DEVICE AWAY FROM WATER RAIN AND HIGH HUMIDITY IT IS...

Page 4: ...UNTERS 12 STEP 3 CONNECTING THE COUNTER TO THE ETH MODEM 14 STEP 4 SETTING THE DISTANCE BETWEEN THE COUNTERS 15 STEP 5 MOUNTING THE COUNTERS TO THE SUFRFACE 16 STEP 6 COUNTER CONFIGURATION 17 STEP 7 D...

Page 5: ...atteries 4 1 5 V batteries 2 per each counter block Adhesive pads type 1 2 Pads for mounting the counter on a surface Adhesive pads type 2 2 Pads for mounting the counter on a surface Screws 4 Screws...

Page 6: ...t each other they create two beams between them Each time the beams are crossed block R detects the fact of crossing and its direction stores that data and later transfers it to the Ethernet modem as...

Page 7: ...ETH modem see the manual Infrared band 990 nm Dimensions 42 mm height 68 mm length 18 mm width Direction indicator Bi directional counting BLUE RED Unidirectional counting BLUE RED Photovoltaic cells...

Page 8: ...protocol OMEGA XML JSON TXT Modem interface ETH through operating systems WINDOWS LINUX iOS Power supply 1 5 V batteries 2 per each counter block Battery change is carried out by the user Power consum...

Page 9: ...password use the password changing option in Settings Administration Double click to open settings window Change to necessary settings 9 DEFAULT SETTINGS IP 192 168 1 218 MASK 255 255 255 0 GATEWAY 19...

Page 10: ...F THE MODEM THE TIME IS SET FROM SNTP TIME SERVERS IF THE NETWORK IS CLOSED SET UP A SEPARATE TIME SERVER AND PUT ITS DETAILS IN THE SETTINGS TIME ZONE IS TO BE CHOSEN CORRECTLY TIME IS TO BE SET IF T...

Page 11: ...rotective black screen Opening the casing Installing batteries in blocks R and T Install batteries into holders with correct polarity as shown on the picture below POLARITY MUST BE FOLLOWED CORRECTLY...

Page 12: ...R block for connection to the ETH modem Open the counter casing and press the button Service while the program is scanning as shown on the picture below Press the button at the moment when the program...

Page 13: ...needed for the T block Connecting additional counters and adding them to OMEGA ETH program If there are additional pairs of counters follow the same connection process as described before for the R bl...

Page 14: ...sary to configure the T block by setting the correct distance between the blocks Open the casing of the T block and set the distance on it by moving the correct switch to the right as shown on the pic...

Page 15: ...cture below Main recommendation when mounting counters blocks fix the counters so that the R block is facing the ETH modem When mounting the counters mind the door handles they should not be in the co...

Page 16: ...ltaneously no need to additionally divide end values by two Entrance indicator If the indicator is red when someone enters put in RED if the indicator is blue when someone enters put in BLUE Important...

Page 17: ...t OMEGA CLOUD connecting the counter to cloud analytics with the possibility to view data via any browser and smartphone HTTP S packet data transfer in JSON or XML format to a server that supports TLS...

Page 18: ...ND A REQUEST TO info megacount io When you are connected to the analytics program it will be possible to view data with a browser on any PC laptop or smartphone Name Any name ID for the data export e...

Page 19: ...ACCEPTED TEXT MESSAGE ONLY THEN WILL THE PROGRAM SEND THE NEXT DATA PACKET HTTP S settings Name Any name ID for the data export e g Analytics My data export etc Protocol http or https with TLS encrypt...

Page 20: ...wing end value one day many files File name Compound file name format ID and CD tags are obligatory Port Port address of the server to which the data will be pushed URI Receiving script resource ID Se...

Page 21: ...tor The counter confuses In and Out directions at a large distance It is recommended to switch the counter to the unilateral counting mode choose unilateral counting mode in the counter settings wait...

Page 22: ...at have accepted the recycling system This marking implies prohibition of disposing of the equipment together with other household waste Device contains batteries If disposed of incorrectly batteries...

Page 23: ...as intended indoors under normal conditions Service life 7 years Warranty 1 year MEGACOUNT MANUFACTURER MEGACOUNT LTD 73472165005 134 Mendeleeva St UFA 450022 Russia info megacount io megacount io EAC...