background image

4

Safety Precautions

The purpose of safety precautions are to 
attract your attention to possible dangers. 
The safety symbols and the explanations 
with them, require your careful attention 
and understanding. 

The safety warnings by themselves do not 
eliminate any danger. The instructions or 
warnings they give are not substitutes for 
proper accident prevention measures.

The following symbols may appear in this 
User Guide, on the Control Unit, or on its 
accessories. Some of the symbols represent 
standards and compliances associated with 
its use.

 SAFETY ALERT SYMBOL: 

Indicates 

caution or warning. 

 

WARNING: 

Failure to obey a safety 

warning can result in serious injury  
to yourself or to others. Always follow 
the safety precautions to reduce the 
risk of fire, electric shock and  
personal injury.

 

DOUBLE INSULATION

Double insulation is a safety concept of 
electrical equipment which eliminates 
the need for earth grounding. Whenever 
there is electric current in the Control Unit 
there are two complete sets of insulation 
to protect the user. All exposed metal parts 
are isolated from the internal metal motor 
components with protecting insulation.

 WARNING: 

The double insulated 

system is intended to protect the user from 
shock resulting from a break in the Control 
Unit’s internal wiring. Observe all normal 
safety precautions related to avoiding  
electrical shock.

 WARNING: 

Servicing a Control Unit 

with double insulation requires extreme 
care and knowledge of the system and 
should only be performed by a qualified 
service technician. For service we suggest 
you return the Control Unit to your nearest 
Medistore Authorised Service Centre for 
repair. When servicing, use only identical 
replacement parts.

 

OPERATING INSTRUCTIONS

 WARNING: 

Do not attempt to operate 

this product until you have thoroughly 
read and completely understand the safety 
rules, etc contained in this User Guide. 
Failure to comply can result in accidents 
involving fire, electric shock or serious 
personal injury. Save this User Guide 
and review frequently for continual safe 
operation and for instructing others who 
may use this product.

 

Maximum recommended patient 

weight for this system is 120kg.

 

Only the Control Unit and  

Mattress combination as recommended  
by Medistore should be used, otherwise 
the correct function of this product cannot 
be guaranteed.

Summary of Contents for ProCair 3000

Page 1: ...User Guide ProCair 3000...

Page 2: ...fore operating this medical equipment it is important to read this User Guide and understand the operating instructions and safety precautions Failure to do so could result in patient injury and or da...

Page 3: ...allation 7 Unpacking Inspection 7 System Installation 8 Control Unit Installation 8 Operation 9 Control Unit Panel 9 Removal and Transport Function 10 Troubleshooting 11 Maintenance and Cleaning 12 13...

Page 4: ...are isolated from the internal metal motor components with protecting insulation WARNING The double insulated system is intended to protect the user from shock resulting from a break in the Control Un...

Page 5: ...grounded power receptacle and use the power cord supplied with the system Exposure of the electronic Control Unit to any liquid while it is plugged in could result in a severe electrical hazard Medist...

Page 6: ...y It is controlled by a simple analogue interface with a dial to control comfort settings and a visible alarm to warn of system low pressure or power failure On the left side of the Control Unit are t...

Page 7: ...ess Overlay and accessories from the shipping cartons Inspect all items for any damage that may have occurred during shipping Any damage or missing components should be reported to a Medistore Service...

Page 8: ...lation a Position Control Unit by its hanging hooks over foot board of the bed or on the floor under the bed b Attach two inflation air hoses to Control Unit with the press on quick release connectors...

Page 9: ...air cells and therefore coming in contact with mattress You should be able to slide your hand between the cells underneath the patient s sacral area bottom along a cell that is deflated Ensure patien...

Page 10: ...minutes for the setting to take effect 2 Ensure that the overlay is not currently undergoing an alternation If not then turn off Control Unit and disconnect both hoses Immediately connect the air hose...

Page 11: ...hoses along the inside of the overlay each should be firmly connected Check each air cell is securely attached to the connecting air pipe Check all cells pipes and hoses for any air leakage Check that...

Page 12: ...TION Do NOT dry the Top Cover using the HEAT cycle or a dryer Air dry or select a low or NON heat dry cycle Washing Alternative If there are no visible signs of body fluids and or substances on the to...

Page 13: ...to prevent scratches 4 Carefully pry off the cover of the air filter remove and discard the filter material and fit new there may be a small locking screw use a small Philips head to remove this firs...

Page 14: ...th 2000mm Width 880mm Height 90mm Weight 8 4kgs Control Unit Dimensions Weight Height 115mm Width 135mm Depth 270mm Weight 2 1kgs Power Rating 12VA Cells 21 cells Cell material 0 15mm TPU film laminat...

Page 15: ...roblem failure is due to customer damage negligence and or misuse unauthorised repairs Items not covered under warranty include but are not limited to stains punctures cuts damages to electrical cords...

Page 16: ...the CE mark in accordance with EC Directive on Medical Devices 93142lE EC Control Number 95CG Classified by Underwriter s Laboratory Inc for UL 2601 1 standard for Medical Electrical Equipment Medist...

Reviews: