If the instrument uses 3V manganese or alkaline dry cell (2 AAA batteries), when LCD displays 
“          ”, it indicates that the battery has been in a low power state. The battery must be replaced as 
soon as possible to ensure the accuracy of the measurement. Meanwhile, after the replacement of 
components (such as batteries) and the thermometer reaches the end of its equipment life, please 
handle it according to local laws and regulations.

 

 
Precautions for Installing or Replacing Battery 

 

 

Attentions 

1. When opening the battery cover to replace the battery, pay attention to 
the correct position of the positive and negative poles. Please take out the 
battery immediately after use. Misplacement may cause product damage. 
2. When it is not to be used for a long time, please take out the battery to 
prevent the thermometer from being damaged due to battery leakage. 
3.  Do  not  use  the  infrared  thermometer  when  the  battery  leaks  or  gets 
moldy. 
4. Do not put the battery close to the fire source or into the fire in case of 
battery explosion. 
5. Do not store the battery in high temperature or high humidity. 
6. To avoid short circuit, do not put the battery in the same pocket or other 
containers with metal objects such as coins or keys, or in the containers that 
may cause short circuit. 
7. In case the electrolyte in the battery accidentally enters the eyes, please 
wash  the  eyes  with  plenty  of  water  immediately.  If  there  is  a  risk  of 
blindness  and  other  injuries,  immediately  go  to  the  nearest  hospital  for 
treatment. 
8. In case the electrolyte in the battery is accidentally on the skin or clothes, 
please wash it with plenty of water immediately, otherwise it may damage 
the skin. 

Notes 1. The emissivity of different materials may be different, so please refer to the emissivity of 
materials. The  default  emissivity  of  this  product  is  1.0. With  different  emissivity,  the  measured 
temperature will different from the actual temperature. 

4. Operation steps 

4.1 measurement operation 

(1) When the thermometer is in the temperature measurement mode, hold and press the measuring 
button to start up, the instrument will self-check. After one second, the buzzer will send out the 
corresponding prompt sound, and the measurement results will be displayed on the display screen. 
When  the  corresponding  backlight  is  turned  on,  and  the  temperature  can  be  measured  again  by 
pressing the measuring button. 
(2) Make sure that the thermometer is 5cm ~ 10cm vertical to the forehead (Figure 1). Then press 
the measuring button by finger. When the measurement is completed, the temperature result will be 
displayed (Figure 2). 

Summary of Contents for XL-F02

Page 1: ...Instruction Manual Medical Infrared Thermometer Specification and Model XL F02 Please read the manual before use Period of use three years Version A 0 ...

Page 2: ...ay Icon Definition 7 Contraindications Precautions Warnings and Suggestive Instructions 8 Daily Maintenance Cleaning Maintenance and Maintenance Interval 9 Names and Contents of Toxic and Harmful Substances or Elements in the Product 9 Parts List 10 Explanation of Signs Conformity Abbreviations etc used in Medical Device Labels 10 Troubleshooting 10 Clinical Accuracy 11 Statement 11 Description of...

Page 3: ...erspires please aim at the earlobe for measurement And make sure there is no hair sweat cosmetics or hat worn Note It s normal that the measured temperature value maybe different varying from skin color thickness to different parts of human body as well as large changes in ambient temperature The more exposed the human body is the more easily and largely the temperature is affected by ambient temp...

Page 4: ... 42 9 Maximum Permissible Error The maximum allowable error of thermometer is 0 2 within 35 0 42 0 the maximum allowable error is 0 3 beyond 35 0 42 0 Display Resolution 0 1 Measuring Distance 5cm 10cm Operating Environment Temperature 16 35 Relative Humidity 80 Atmospheric Pressure 86kpa 106kpa Transportation and Storage conditions Temperature 20 55 Relative Humidity 93 Atmospheric Pressure 50kPa...

Page 5: ... each component and maintain the good performance of the thermometer 2 Keep the power supply sufficient 3 After the product is packed it is allowed to use the common means of transportation but it should avoid rain moisture and mechanical collision of extrusion box 2 Unpacking Open the color box which is with single package take out the plastic box with thermometer and then open the plastic box to...

Page 6: ...l objects such as coins or keys or in the containers that may cause short circuit 7 In case the electrolyte in the battery accidentally enters the eyes please wash the eyes with plenty of water immediately If there is a risk of blindness and other injuries immediately go to the nearest hospital for treatment 8 In case the electrolyte in the battery is accidentally on the skin or clothes please was...

Page 7: ... close to the stove and do not let it come in contact with water 7 Please do not bump or drop the product and do not use if it is damaged 8 Hair sweat hat or scarf on forehead will affect the accuracy of measurement figure 9 Please ensure the measurement distance is not farther than 5cm 10cm 10 In order to obtain accurate stable and reliable measurement figure when the room temperature changes gre...

Page 8: ...ting F2 is the fever alarm F3 is the prompt sound switch F4 is the temperature compensation setting F5 is the infrared ray switch Display Icon Definition Display Icon Definition Icon State Description Electricity Indication Display Low power and only for a short time work Display and flash Extremely low power and impossible for normal work Immediate Replacement of the battery is recommended No dis...

Page 9: ...ke the body temperature check when the temperature is consistent with the ambient temperature 4 The environment around the tested person should be stable and he she can t be tested in places with large air flow such as fan air conditioner outlet etc 5 Do not use the instrument outdoors or in a sunny place 6 Do not hold the front of the thermometer with your hand when measuring 7 The measuring area...

Page 10: ...not place the thermometer in a place where there is too high or too low temperature damp or direct sunlight dust or corrosive gas 5 If the thermometer is not to be used for a long time more than 3 months please take out the battery for safekeeping 6 It is recommended that user should maintain the thermometer every 3 months Calibration and maintenance The accuracy of this thermometer has been stric...

Page 11: ...tion Manual Certificate Warranty card 1 Explanation of Signs Conformity Abbreviations etc used in Medical Device Labels Signs 1 Signs on products and packages Reference for use Attention please refer to the attached documents Type B application equipment Keep dry Low voltage prompt Avoid sun exposure Straight up Fragile please handle it with care Safety Critical Parts List Key parts list MCU senso...

Page 12: ...ter environment the human body is the more easily and greatly the temperature is affected Statement The temperature of the person is attained by measuring the thermal radiation on the forehead of the human body The clinical accuracy or clinical deviation of the thermometer has got the clinical verification and its safety and effectiveness meet the requirements of relevant national laws and regulat...

Page 13: ...ition to the cables sold by the manufacturer of the machine as spare parts of internal components the use of accessories and cables other than those specified may cause the increase of emission or decrease of anti interference of the medical infrared thermometer Other Guideline and Statement from Manufacturer Electromagnetic Emission Xl F02 medical infrared thermometer is expected to be used in th...

Page 14: ...ith synthetic material the relative humidity shall be at least 30 Electrical fast transient burst EFT B GB T 17626 4 2kV power supply cord 1kV For input output lines N A N A Electrical Surge GB T 17626 5 1 kV Differential mode voltage 2 kV Common mode voltage N A N A Voltage sag on power input line short time medium time Break and voltage change GB T 17626 11 5 UT for 0 5 cycles on UT 95 sag 40 UT...

Page 15: ...ided by transmitter manufacturer in watts W d Recommended isolation distance in meters m b The field strength of the fixed RF transmitter is determined by surveying the electromagnetic field C in each frequency range d should be lower than the compliance level Interference may occur near equipment marked with the following symbols Radiofrequency conduction GB T 17626 6 3 V Effective Value 150 kHz ...

Page 16: ... buyer or user can prevent electromagnetic interference by maintaining the minimum distance between portable and mobile RF communication equipment transmitter and equipment or system as recommended below Rated maximum output power of transmitter W Isolation distance corresponding to different frequencies of transmitter M 150 kHz 80 MHz d 1 2 80 MHz 800 MHz d 1 2 800 MHz 2 5 GHz d 2 3 0 01 N A 0 12...

Page 17: ...ilure caused by unauthorized folding and refitting of the product 2 Machine failure caused by careless falling during taking or using 3 Failure caused by improper operation without following the operation method in this manual 4 Failure caused by natural disasters such as earthquake fire etc 5 Failure caused by improper maintenance of maintenance shop not authorized by the company Name Contact Cus...

Page 18: ...unity Humen Town Dongguan City Guangdong Province P R China Product Technical Requirement No Verification for Canton Instrument 20192071228 Medical device registration certificate No Verification for Canton Instrument 20192071228 Production license No Guangdong food and Drug Administration machinery production license 20193511 Product batch No see the machine body Period of use 3 years Release dat...

Reviews: