CHAPTER 2
| CONNECTIONS
The lever extension motor is activated with a single output control line. By turning the output
bit “ON” the lever will extend into the chamber. When the output bit is turned “OFF” the lever
will retract out of the chamber. When the animal depresses the lever the signal is received on
the input bit.
Operate Connector
Operate connects to any available Output on a Standard MED Connection Panel via an included
SG-216A cable.
Molex Pin #
Function
Wire Color
1
28 Volt Ground
Black
2
Extend/Retract Lever
White
3
+28 Volts
Red
Response Connector
Response connects to any available Input on a Standard MED Connection Panel via an included
SG-216A cable.
Molex Pin #
Function
Wire Color
1
28Volt Ground
Black
2
Lever Response
White
3
+ 28 Volts
Red
*Optional Lever Position Connector
A lever position feature has been added to the circuitry of this low profile lever. When the lever
is extended, a signal is sent to an Input bit. The signal is turned off when the lever is retracted.
Lever Position connects to any available Input on a Standard MED Connection Panel via an
included SG-216A cable.
Molex Pin #
Function
Wire Color
1
28Volt Ground
Black
2
Lever Position
White
3
+ 28 Volts
Red