Inputs/outputs modules: MPNE
Mect Srl
36
ME7087_13 04/21
12 Update Fast Input
14 Update Fast OUT
15
1 = Bit Set
0 = Bit Reset
To set bit 1 (Fast In managed) write:
MPNE_ControlWord_B :=
16#8002;
To reset bit 2 (Fast OUT managed)
write:
MPNE_ControlWord_B :=
16#0004;
MPNE_ControlWord_
B1
MPNE_ControlWord_
C1
MPNE_ControlWord_
D1
UINT
Variable for control of special functions.
LINE: B
,
C
,
D
bit
1 Steady state OUT (High or Low)
If set to 1, the output is ON, and returns to
OFF when the trigger condition intervenes.
If set to 0 the output is OFF, and returns to
ON when the trigger condition intervenes
MPNE_FastInDelay_x
UINT
Time value expressed in:
µs for LINE A
ms for LINE B,C,D
MPNE_FastOutDelay_x
UINT
Time value expressed in:
µs for LINE A
ms for LINE B,C,D
MPNE_FastOutDuration_x
UINT
Time value expressed in:
µs for LINE A
ms for LINE B,C,D
MPNE_EncCounter_x
DINT
Encoder counter
MPNE_MatchRegister_x
DINT
Number of counts reached when the
associated output (if enabled) goes to ON
and remains there until it is expressly reset