Inputs/outputs modules: MPNE
Mect Srl
34
ME7087_13 04/21
B,C,D
min: 1ms
max: 65s
Res.: 1ms
Acc.: 1ms
2
Monostable output
delayed with respect to
the input
The output goes ON with a delay with
respect to the arrival of the associated
input and remains ON for the set time
For B, C and D lines, the exit is self-
retriing. In practice, you don't need to
rewrite the variable to trigger the event
again.
NOTE: If the input is not put OFF the
output returns to ON after the set
delay time.
A
min: 100µs
max: 65ms
Res.: 1µs
Acc.: 20µs
B,C,D
min: 1ms
max: 65s
Res.: 1ms
Acc.: 1ms
3
Monostable output
Following a command from the PLC,
the output remains ON for the set time
and then returns to OFF
A
min: 100µs
max: 65ms
4
Output at the end of the
PTO
Output goes to ON at the end of the
PTO count.
A
5
PTO start synchronized
with the input
The PTO starts after the associated
input 13 has been detected. If a delay
is set on the input, the PTO starts at
the end of the time
A
6
PTO start following a
PLC command
The PTO starts after the PLC receives
a start command
A
7
Output ON when
matching value is
reached on the encoder
OUT 1 goes ON when the count value
reaches the value on the matching
register.
OUT 1 goes OFF after an encoder
reset.
A
8
Encoder reset via fast
input
Rising fast input (IN13) resets
encoder value.
A