INSTALLATION AND PUTTING INTO OPERATION
2.1 Duties which are the responsibility of the user
The environmental conditions in the place where the machine is installed must have the
following characteristics:
·
Must be without humidity
·
Must have sources of water and heat at an adequate distant
·
Must have suitable ventilation and lighting which reflect the sanitary and safety regulations
according to the current legislation. The floor must be flat and compact in order to favour
adequate cleaning. Obstacles of any nature which could effect normal ventilation must not be
placed in the immediate vicinity of the machine.
INFORMATION
The electrical supply must be fitted with a differential circuit breaker, with characteristics
which are adequate for the machine, in which the aperture distance between the contacts
is at least 3mm. In particular, it is essential that an efficient ground point is provided.
ATTENTION
Verify that the voltage supply and the frequency of the plant are compatible with the values
listed both in the technical details (1.3) and on the plate located on the back of the machine.
2.2 Installation procedure
The machine is supplied in an apposite closed box and fixed with plastic strapping to the
wooden pallet. Inside the packing, as well as the machine, there are the usage manual and
the conformity declaration relating to machinery directives. The machine must be unloaded
from the delivery vehicle by lifting with suitable equipment.
Use a wheel trolley with adequate loading capacity for transporting the machine to its the
place of installation. After having cut the plastic strapping, remove the packaging and plastic
protection. With the help of belts with a suitable loading capacity inserted under the base of
the machine (FIG. 3) and a suitable means of lifting (manual or motor driven), lift the machine,
remove the pallet found underneath it, and place it in the desired position ensuring to take
care to leave free space around it of approximately 50 cm in order to facilitate the operations
of use, cleaning and maintenance of the machine itself. In the case of an instability of the
machine due to floor irregularities, thicken the wheels or feet with hard rubber plates.
For correct levelling of the machine, use feet A (FIG. 4).